1.1
Installation of MVHR unit (Refer to MVHR owners manual)
Securely fasten and level the
fixing bracket (allow for drain
area below the unit).
Position unit onto bracket.
Ensure unit has small fall to
drain.
Install a condensation drain to
the unit with a waterless trap.
It is recommended that this is
connected to a 32mm waste
pipe (within 1m of the unit)
going into an internal drain.
If an internal drain is not
possible insure pipe has
sufficient fall and is protected
from freezing.
The waterless trap and
condensation drain is
available as an additional
accessory to our kits
We recommend you install
boost switches outside the
bathrooms, 2 gang switches
are also available that
incorporate the light switch.
1.2
Installation of MVHR controls (Refer to MVHR owners manual)
1.3
Installation of Condensation drain (Refer to owners manual)
If available, we recommend
the installation of the MVHR
controller be positioned in the
kitchen/utility room or plant
room.
Some units require additional
room sensors to detect
moisture or Co2.