B4-1KB 

B4-1KB

   

 

8. SPECIFICATIONS: 

1200VA 

1700VA 

2200VA 

CAPACITY

 

700W 

1050W 

1400W 

INPUT             Voltage 

Frequency 

Selectable 100/110/115/120V 1ø or 200/220/230/240V 1ø  

50Hz/60Hz Auto detect 

 

Current (110V/220V) 

12A / 6A 

16A / 8A 

21A / 10A 

Voltage 

100/110/115/120V 1ø or 200/220/230/240V 1ø 

±6% for Back-up Mode 

 

<  

±10% for AVR 

Frequency  50Hz or 60Hz ± 0.1Hz (Selectable under DC start) 

OUTPUT 

Wave Form  Simulated Pseudo Sine Wave 

 

 

Current (110V/220V) 

11A / 5.5A 

15.5A / 7.8A 

20A / 9.8A 

TRANSFER TIME 

4 ms typical. 

BATTERY         

 

Lead-Acid, maintenance free 

Voltage/Capacity 

12V 7Ah X 2pcs 

12V 7Ah X 3pcs 

12V 7Ah X 4pcs 

Level Ind.  

YES 

YES 

YES 

Recharge Time 

90% within 4 hrs 

LED/ALARM INDICATION 

 

Normal/In charge 

GRN LED, No Beep. 

Back up / Abnormal Input Voltage  ORG LED Flashing, 2 Beeps / 8 sec.   

Abnormal Input Frequency 

(Back up)

  ORG LED Rapid Flashing, 2 Beeps / 8 sec.   

Green mode auto off 

ORG LED flashing, 1 Beep / 4 sec. (Auto off after 24 sec.) 

Low Battery 

ORG LED Flashing, 4 Beeps / sec. 

Battery Replacement 

RED LED Flashing, 8 Beeps/ sec.   

Over Load/Fault 

RED LED Flashing, Continuous Beep. 

INDICATION OF SPECIAL STATUS 

Replace Battery / Alarm Off / Charging / Buck / Boost 

DC START / ALARM RESET 

YES 

YES 

YES 

BATTERY LOAD INDICATION 

YES 

YES 

YES 

ENVIRONMENT TEMP.  

0 - 37 

?

 

ENVIRONMENT HUMIDITY 

30-95% Non-Condensing 

DIMENSIONS (L x H x W)   

(cm) 

38 x 20 x 18 

44 x 20 x 18 

51 x 20 x 18 

SHIPPING DIM. (L x H x W)   

(cm) 

48 x 33 x 30 

54 x 33 x 30 

61 x 33 x 30 

WEIGHT (N.W. / G.W.)      

(kgs) 

15/16 

21.50/22.50 

25/26 

 

 

 

1. 

INTRODUCTION 

1.1  Overview: 

The PowerStar series UPS is an advanced high performance stand by 
Uninterruptible Power System (UPS)  designed to protect your 
computer from utility line failure.  In the event of utility failure  
(blackout), the UPS will rapidly transfer loads to an alternative power 
source, which derives power from battery set inside the UPS. 
The UPS provides two charging mode, quick charging and trickle 
charging, to maintain  the batteries in  the  best condition.   Battery 
status indication, including capacity, low battery condition, charging 
condition, and replace battery condition, are shown on the front panel. 

1.2    Battery Replacement warning 

The self-test function (real-time detection) will inform you with an 
alarm when the batteries are weak and require replacement. 

1.3    Smart-AVR 

The UPS automatically corrects output voltage within the normal range, 
both in low utility voltage (“

Boost

” LED lights up) and high utility voltage 

(“

Buck

” LED lights up) conditions. 

 

2. 

MAIN FEATURES:

 

?  

Microprocessor based design. 

?  

Advanced indication for special operation status. 

?  

Green mode function. 

?  

Auto select input frequency 50Hz/60Hz. 

?  

Self test function. 

?  

Battery replacement indication. 

?  

Extra wide-range AVR function. 

?  

Standard RS-232 port for monitoring function. 

?  

Double protections for over load & short circuit. 

 

11                                                                                     4

Summary of Contents for PowerStar series 1200

Page 1: ...uptible Power System THE BRITISH POWER CONVE RSIONCOMPANY User s Manual PowerStar Series 1200 1700 2200 100 80 60 40 20 Replace Battery Alarm Off Charging B u c k Boost BATTERY LEVEL SPECIAL STATUS NORMAL BACK UP LOW BATT OVER LOAD ...

Page 2: ...ge 5 4 INSTALLATION AND OPERATION Page 5 6 4 1 Installation 4 2 Operation 4 3 Audible alarm 5 INDICATION AND CONTROL Page 7 8 5 1 Battery level LEDs 5 2 Special status LEDs 5 3 Auto self test function 5 4 Status LED and Alarm indication 5 5 Reset the UPS 6 COMMUNICATION INTERFACE Page 9 7 TROUBLE SHOOTING Page 10 8 SPECIFICATIONS Page 11 9 IMPORTANT SAFETY INSTRUCTIONS Page 12 MEMO 1 ...

Page 3: ...f battery voltage level LEDs of UPS special status LED of operation status Control button 2 1 3 4 2 1 4 NORMAL BACK UP LOW BATT OVER LOAD BATTERY LEVEL SPECIAL STATUS Replace Battery Alarm Off Charging B u c k Boost 100 80 60 40 20 3 13 2 ...

Page 4: ...ated by any individuals without any previous experience The socket outlet shall be installed near the equipment and easily accessible With the installation of this equipment it should be prevented that the sum of the leakage current of the UPS an the connected consumer does not exceed 3 5mA Attention hazardous through electric shock Also with disconnection of this unit from the main hazardous volt...

Page 5: ... cm 38 x 20 x 18 44 x 20 x 18 51 x 20 x 18 SHIPPING DIM L x H x W cm 48 x 33 x 30 54 x 33 x 30 61 x 33 x 30 WEIGHT N W G W kgs 15 16 21 50 22 50 25 26 1 INTRODUCTION 1 1 Overview The PowerStar series UPS is an advanced high performance stand by Uninterruptible Power System UPS designed to protect your computer from utility line failure In the event of utility failure blackout the UPS will rapidly ...

Page 6: ...rated for at least 20 Amps Connecting your equipment to the UPS To ensure that your computer equipment will be protected during a utility failure it is important to make sure that the maximum power need of the equipment is not over the rated capacity of the UPS When blackout happens LED of operation status will become red and alarm will beep if the load is over the rated value Meantime if the over...

Page 7: ...e of self test about 3 4 sec If test results are O K the green LED will be on 4 2 2 Pushing the button for 3 seconds the UPS will turn off the power But the red LED will remain blinking when the AC power cord is connected To turn off the power completely please pull out the power cord For turning on the UPS again please connect back power cord and push the button 4 2 3 During blackout push the but...

Page 8: ... connecting a low utility voltage The loads receive normal power The Buck LED would be on when the UPS is connecting a high utility voltage The loads receive normal power 5 3 Auto self test function In normal mode of UPS turn on your computer and push the button on the front panel for self test The UPS will simulate a power outage and transfer your load to the UPS s battery If low battery warning ...

Reviews: