8. SPECIFICATIONS:
1200VA
1700VA
2200VA
CAPACITY
700W
1050W
1400W
INPUT Voltage
Frequency
Selectable 100/110/115/120V 1ø or 200/220/230/240V 1ø
50Hz/60Hz Auto detect
Current (110V/220V)
12A / 6A
16A / 8A
21A / 10A
Voltage
100/110/115/120V 1ø or 200/220/230/240V 1ø
±6% for Back-up Mode
<
±10% for AVR
Frequency 50Hz or 60Hz ± 0.1Hz (Selectable under DC start)
OUTPUT
Wave Form Simulated Pseudo Sine Wave
Current (110V/220V)
11A / 5.5A
15.5A / 7.8A
20A / 9.8A
TRANSFER TIME
4 ms typical.
BATTERY
Lead-Acid, maintenance free
Voltage/Capacity
12V 7Ah X 2pcs
12V 7Ah X 3pcs
12V 7Ah X 4pcs
Level Ind.
YES
YES
YES
Recharge Time
90% within 4 hrs
LED/ALARM INDICATION
Normal/In charge
GRN LED, No Beep.
Back up / Abnormal Input Voltage ORG LED Flashing, 2 Beeps / 8 sec.
Abnormal Input Frequency
(Back up)
ORG LED Rapid Flashing, 2 Beeps / 8 sec.
Green mode auto off
ORG LED flashing, 1 Beep / 4 sec. (Auto off after 24 sec.)
Low Battery
ORG LED Flashing, 4 Beeps / sec.
Battery Replacement
RED LED Flashing, 8 Beeps/ sec.
Over Load/Fault
RED LED Flashing, Continuous Beep.
INDICATION OF SPECIAL STATUS
Replace Battery / Alarm Off / Charging / Buck / Boost
DC START / ALARM RESET
YES
YES
YES
BATTERY LOAD INDICATION
YES
YES
YES
ENVIRONMENT TEMP.
0 - 37
?
ENVIRONMENT HUMIDITY
30-95% Non-Condensing
DIMENSIONS (L x H x W)
(cm)
38 x 20 x 18
44 x 20 x 18
51 x 20 x 18
SHIPPING DIM. (L x H x W)
(cm)
48 x 33 x 30
54 x 33 x 30
61 x 33 x 30
WEIGHT (N.W. / G.W.)
(kgs)
15/16
21.50/22.50
25/26
1.
INTRODUCTION
1.1 Overview:
The PowerStar series UPS is an advanced high performance stand by
Uninterruptible Power System (UPS) designed to protect your
computer from utility line failure. In the event of utility failure
(blackout), the UPS will rapidly transfer loads to an alternative power
source, which derives power from battery set inside the UPS.
The UPS provides two charging mode, quick charging and trickle
charging, to maintain the batteries in the best condition. Battery
status indication, including capacity, low battery condition, charging
condition, and replace battery condition, are shown on the front panel.
1.2 Battery Replacement warning
The self-test function (real-time detection) will inform you with an
alarm when the batteries are weak and require replacement.
1.3 Smart-AVR
The UPS automatically corrects output voltage within the normal range,
both in low utility voltage (“
Boost
” LED lights up) and high utility voltage
(“
Buck
” LED lights up) conditions.
2.
MAIN FEATURES:
?
Microprocessor based design.
?
Advanced indication for special operation status.
?
Green mode function.
?
Auto select input frequency 50Hz/60Hz.
?
Self test function.
?
Battery replacement indication.
?
Extra wide-range AVR function.
?
Standard RS-232 port for monitoring function.
?
Double protections for over load & short circuit.
11 4