Installation and Wiring Instructions for the Silent Range of Extractor Fans.
IMPORTANT: READ THESE INSTRUCTIONS BEFORE COMMENCING THE
INSTALLATION
DO NOT install this product in areas where the following may be present or occur:
•
Excessive oil or a grease laden atmosphere.
•
Corrosive or flammable gases, liquids or vapours.
•
Ambient temperatures higher than 40°C or less than –5°C.
•
Possible obstructions which would hinder the access or removal of the Fan.
SAFETY AND GUIDANCE NOTES
A.
All wiring to be in accordance with the current I.E.E. Regulations, or the appropriate
standards of your country and
MUST
be installed by a suitably qualified person.
B.
The fan should be provided with a local isolator switch capable of disconnecting all poles,
having a contact separation of at least 3mm.
C.
Ensure that the mains supply (Voltage, Frequency, and Phase) complies with the rating
label.
D.
The fan should only be used in conjunction with the appropriate Vent-Axia products.
E.
The fan should only be used in conjunction with fixed wiring.
F.
When the fan is used to remove air from a room containing a fuel-burning appliance, ensure
that the air replacement is adequate for both the fan and the fuel-burning appliance.
G.
The fan should not be used where it is liable to be subject to direct water spray for
prolonged periods of time.
H.
Where an excessive amount of moisture is present in the air, a condensation trap will
need to be installed in the exhaust duct. Horizontal ducts should slope away from the
fan unit. Ducts passing through an unheated roof void should be insulated.
I.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
J.
Children should be supervised to ensure that they do not play with the appliance.
K.
Stationary appliances not fitted with means for disconnection from the supply mains having
a contact separation in all poles that provide full disconnection under over voltage category
III, the instructions state that means for disconnection must be incorporated in the fixed
wiring in accordance with the wiring rules.