8A
call common 2 output
11
audio from entry panel
12
audio to entry panel
23
output 14 V AC
16
NO
normally open
relay
C
common
contacts
NC
normally closed
Terminal block C
5
ground
8
audio to receiver
9
audio from receiver
Technical features
• Supply voltage: 230 V, 50/60 Hz.
The transformer is electronically pro-
tected against overloading and short
circuiting i. e. no fuses are used.
The unit can be powered from a 12 V
DC power supply, e. g. battery or
uninterruptable power supply (termi-
nals +B and 5).
NOTE. The unit has no battery pro-
tection.
• Rated power: 15 VA.
• Output voltages:
11 VDC 150 mA (300 mA peak)
14 VAC, 650 mA (1 A in intermittent
current).
• Call generator: 2 types of two-tone
call (up to 3 internal units can be con-
nected in parallel to the same call).
• Working temperature range: from 0
°C to +35 °C.
• Dimensions: 4 DIN units module, low
profile, figure 2.
The power supplier can be installed
without terminal covers into boxes provi-
ded with DIN rail (EN 50022).
Dimensions are shown in figure 2A.
It can also be surface mounted, using
the DIN rail supplied, but fitted with ter-
minal covers.
Dimensions are shown in figure 2B.
NOTE. The transformer primary is elec-
tronically protected against overloading
and short circuiting i. e. no fuses are
used.
Procedure to reset a triggered circuit:
- Disconnect the mains from the unit.
- Remove the cause of malfunction.
- Let the equipment to cool for at least 1
minute.
- Reconnect the mains to the unit.
A/200N POWER SUPPLIER
With the same features of A/200R, has
also the following function:
- Power supply and control of electric
lock (12 V AC, 1 A) by means of relay
(inside the unit) with timer-controlled
interval adjustable from 2 to 15 seconds
by means of potentiometer
P1
, figure 3.
• Dimensions: 6 DIN units module, low
profile, figure 4.
C/200 HANDSET
It is equipped with the following con-
trols:
Door lock release button
•
Auxiliary services
The C/200 call tone is electronic, in
addition ER/12 buzzer, figure 7, can be
fitted into the handset.
Function of each terminal
Terminal block C
5
ground
7
call
8
audio from entry panel
9
audio to entry panel
•
button for
•
auxiliary services
Technical features
• Current demand: 7 mA max. (0 mA
quiescent).
• Max. switching capacity of auxiliary
services button contact: max. 24V, 1 A.
• Dimensions: 88x220x70 mm.
D
d
A
H
m
R
T
T
M
-
z
c
-
s
R
•
•
•
•
•
•
N
g
M
m
M
A
M
M
h
Installation instructions
Untighten the fixing screw and remove
the front cover from the back housing,
figure 5. Fix the back housing to the
wall, figure 6A, or to an embedding box,
figure 6B, 6C.
Avoid excessive tightening of the screws
especially when walls are not perfectly
flat.
Make the relative connections and re-fit
the cover.
XC/200 HANDSET
With the same features of C/200.
• Dimensions: 110x224x65 mm.
E/220 TWIN CHANNEL RECEIVER
E/220 can be either surface mounted or
partially recessed in conjunction with
ESP/220, figure 10, or ESI/220, figure 9,
respectively.
It is equipped with the following con-
trols:
Door lock release button
Button to operate stairs light timer or
for any other services as required
Audio button. To be kept depres-
sed to converse
The E/220 call tone is electronic, in
addition ER/12 buzzer, figure 11, can be
fitted into the handset.
Function of each terminal
Terminal block C
1
ground
2
audio to entry panel
3
audio from entry panel
4
call
Terminal block D
1
button for
2
auxiliary services
Technical features
• Current demand: 7 mA max. (0 mA
quiescent).
•
Max. switching capacity of stairs
light button contact: max. 24 V, 1 A.
• Dimensions: 100x172x27 mm.
• Dimensions with ESP/220:
100x172xx42 mm.
• ESI/220 embedding box dimen-
sions: 90x162x24 mm.
Installation instructions
Remove the front grid, figure 8, and fix
the housing to the wall using the provi-
ded screws, figure 9. Connect the wires
and replace the front grid.
CAUTION. For acoustic reasons, the
TM series entry panels must be fitted
with MR/100 remote microphones.
Also, the unit cannot be installed with
panel models Z/1÷3 or E/1÷3 which
must be replaced with the corresponding
models ZC/1÷3.
E/220 should never be used together
with C/200-XC/200 series handsets.
E/220 should never be used together
with XC/220 twin channel receivers
series.
DISPOSAL
Do not litter the environment with pack-
ing material: make sure it is disposed of
according to the regulations in force in
the country where the product is used.
When the equipment reaches the end of
its life cycle, take measures to ensure it
is not discarded in the environment.
The equipment must be disposed of in
compliance with the regulations in force,
recycling its component parts wherever
possible.
Components that qualify as recyclable
waste feature the relevant symbol and
the material’s abbreviation.