Function of each terminal and
wire
(fig. 1)
Terminal block
6
+10÷18 VDC
7
coded call from entry panel
N2
enabling of second call note
12
coded call to porter’s switch-
board
Wires
5
ground
7A
call to receiver
P
call to porter’s switchboard
Programming
- Power up the unit and remove
the
SW
software programming
jumper (fig. 1)
- Send the user code via the
coded call entry panel or the
VPD/100-VPDM/100 porter’s swit-
chboard.
- Insert the
SW
jumper.
N.B. If the programming is carried
out via the porter’s switchboard,
the acknowledgement of the com-
pleted programming is given by the
code sent to the receiver appea-
ring on the display PORTER
CALL.
The unit generates two types of
call note:
a)
continuous bi-tonal note lasting
at least 1 s
b)
rings lasting 0.6 s repeated
every 2 s, for the duration of the
call, with a minimum of 2 rings.
The unit is factory set with the note
type
a
for calls from the entry
panel, and with note type
b
for
2
5
6
calls from the porter’s switchboard
(the connection must be made to
terminal
N2
before note type
b
can
be obtained).
The type of note can be inverted
by sending the code
80160
(block
code) or
13120
(progressive-
mode code) to the unit.
In order to reset the initial condi-
tions, send the code
80161
(block
code) or
13121
(progressive-
mode code) to the unit.
The modification of the call note
must be carried out when in pro-
gramming mode (with the software
jumper
SW
disconnected).
Technical features
• Supply voltage: 10÷18 VDC
• Current demand: 1 mA (105 mA
during the call)
• Maximum number of CD/200
units which can be connected in
a block: 200.
• Working temperature range:
from 0°C to 35°C.
• Dimensions: 52x35x17 mm.
Installation
The coder/decoder must be instal-
led in the receiver by following the
indications given in fig. 2÷6.
For the VM/200 table-top series,
the unit is fitted in an embedding
box.
CD/200
CODER/DECODER CD/200
The unit enables the handsets and
the monitors (200 and EXEDRA
200 series) to be installed in
coded call installations system
200.
A CD/200 must be installed in
GB INSTALLATION
INSTRUCTIONS
200.
A CD/200 must be installed in
each receiver, even in installations
where more than one receiver is
activated by the same call.
An RC/200 call repeater can be
connected in parallel to the recei-
ver.