6.3 Jumper position 

 

The fail mode of the COBALT-mini is factory set as Fail Safe, i.e. in the event of a power cut the COBALT-mini will 
unlock. Before the lock is installed this can be changed to Fail Secure by repositioning the jumper located next to 
the 7-way plug on the end of the lock. Select the desired jumper location as indicated: 
 
 
 
 
 
 
 
 
 
 

 
 

 
 
 
 

 
 
7. OPERATION  

 
 

7.1 Fail Safe Operation 

 

Assume the lock is installed and wired, the door is open and there is voltage applied to the BLUE wire. As the door 
closes the  COBALT-mini senses the door approaching and activates the appropriate  bolt pin to pull the door into 
centre  alignment.  Once  the  first  bolt  pin  has  fully  extended,  the  second  bolt  pin  activates  and  drives  to  its  full 
extension. If the door closes to a centre aligned position quickly then both bolt pins activate at the same time rather 
than  one  leading  the  other.  The  Bolt  Position  and  Door  Position  monitors  will  have  changed  state  as  the  door  is 
moved into place and secured. 
 
To unlock the door, voltage is removed from the BLUE wire. The COBALT-mini will immediately release and will do 
so  even  when  significant  load  is  being  applied  to  the  door.  With  the  door  now  open  the  Bolt  Position  and  Door 
Position monitors change state again. The COBALT-mini will remain unlocked as long as the door is open but will 
instantly re-lock when voltage is applied to the BLUE wire and the door is closed. 
 
In the event of a power failure, voltage is removed from the BLUE wire and the COBALT-mini unlocks. 
 
 

7.2 Fail Secure Operation 

 
Assume the lock is installed and wired, the door is open and voltage is removed from the BLUE wire. As the door 
closes the  COBALT-mini senses the door approaching and activates the appropriate  bolt pin to pull the door into 
centre  alignment.  Once  the  first  bolt  pin  has  fully  extended,  the  second  bolt  pin  activates  and  drives  to  its  full 
extension. If the door closes to a centre aligned position quickly then both bolt pins activate at the same time rather 
than  one  leading  the  other.  The  Bolt  Position  and  Door  Position  monitors  will  have  changed  state  as  the  door  is 
moved into place and secured. 
 
To unlock the door, voltage is applied to the BLUE wire. The COBALT-mini will immediately release and will do so 
even when significant load is being applied to the door. With the door now open the Bolt Position and Door Position 
monitors change state again. The COBALT-mini will remain unlocked as long as the door is open but will instantly 
re-lock when voltage is removed from the BLUE wire and the door is closed. 

 

In the event of a power failure, voltage is removed from the BLUE  wire and the  COBALT-mini locks if the door is 
closed. 
 
 

Fail Safe 

=  Fail Unlocked 

=  Power To Lock 

=  PTL 

Fail Secure  =  Fail Locked 

=  Power To Open 

=  PTO 

Jumper in 

Fail Safe

 position. 

Jumper in 

Fail Secure 

position. 

Summary of Contents for COBALT-mini YD39M

Page 1: ...YD30M COBALT mini INSTALLATION AND OPERATING INSTRUCTIONS...

Page 2: ...T o 4 1 Mechanical o 4 2 Electrical 5 INSTALLATION o 5 1 Mortise Installation o 5 2 Surface installation 6 WIRING o 6 1 Fail Safe connection o 6 2 Fail Secure connection o 6 3 Jumper position 7 OPERAT...

Page 3: ...sition With the door secured and locked the COBALT mini can be given an unlock signal and it will instantly unlock If the door is loaded pre load when the unlock signal is given the COBALT mini will s...

Page 4: ...BQT Solutions SEA Pte Limited Page 3 3 DIMENSIONS 3 1 Lock 3 2 Strike Plate 3 3 Fitting Tab 3 4 Housing Available separately 3 5 Dress Plate Available separately...

Page 5: ...e door is approaching from the right then the bolt pin is at the bottom as indicated below 4 2 Electrical The first consideration is to establish where to run the wires and decide on what feedback is...

Page 6: ...the supplied fitting tabs can be used to secure the lock and strike plate in place The mortise behind the lock body needs to have enough space to accommodate the wiring 5 1 2 Wiring the lock Wires ar...

Page 7: ...determine exactly where the wiring will enter the housing and drill one or two 8mm holes through the housing wall Ensure the holes are on the housing face that goes against the wooden frame Push the...

Page 8: ...glass to give a clean finish The protective coating on the dress plate can be removed once it is in place 5 2 5 Fitting the strike plate into the housing The strike plate is placed into the housing a...

Page 9: ...Door Position Switch WHITE COM 6 1 Fail Safe Connection When wiring the COBALT mini the positive voltage is connected to RED negative is connected to BLACK and a switched positive voltage wire connec...

Page 10: ...ng as the door is open but will instantly re lock when voltage is applied to the BLUE wire and the door is closed In the event of a power failure voltage is removed from the BLUE wire and the COBALT m...

Page 11: ...t after initial power up is 250mA 12VDC and 200mA 24VDC 9 MAINTENANCE The COBALT mini has been lubricated at assembly and applying any other type of lubricant may void the warranty Removing the lock c...

Page 12: ...BQT Solutions SEA Pte Limited Page 11 NOTES Version 3 0...

Reviews: