8. SPECIFICATIONS 

 

 

MATERIALS 

 Bolt Pin 

SS17-4PH, 10mm Thick, 13mm extension 

 Strike Plate 

SS304, 3mm Thick 

 Lock Face Plate 

SS304, 3mm Thick 

MECHANICAL 

 Cycle life 

> 300,000 

 Strike Gap 

< 7mm 

 Holding Force 

> 10,000N  (1000kg) 

 Side Load Release 

> 1,000N  (100kg)

 

 Door Misalignment 

Up to 8mm 

ELECTRICAL  

 Voltage at Lock 

12 

– 24VDC ±15% 

 Current Usage 

Holding Current 

< 50mA@12V 

< 30mA@24V 

 

Operating Current 

< 250mA@12V 

< 200mA@24V 

 

Initial Power Up* 

< 1800mA@12V   < 600mA@24V 

 

 Monitor Switches 

Bolt position 

– 30VDC, 0.1A 

Door position 

– 100VDC, 0.5A 

CERTIFICATIONS 

 Patent 

Pending PCT/IB2013/053737

 

 FCC 

Part 15 Subparts A & B 

– Unintentional Radiators  

 CE 

EN 61000-6-1: 2007, EMC Directive 2001/108/EC Immunity 

EN 61000-6-3: 2007, EMC Directive 2001/108/EC Emissions 

 

         

          

              

*

 Initial power up of the lock requires up to 1800mA@12VDC and up to 600mA@24VDC for up to 6 seconds but only occurs 

 when the power has been completely removed for an extended period then re-applied, for example after a power outage. 

  

 Normal Operating Current after initial power up is <250mA@12VDC and <200mA@24VDC. 

 

9. MAINTENANCE 
 

The COBALT-mini has been lubricated at assembly and applying any other type of lubricant may void the warranty. 
Removing the lock cover may void the warranty. A dry cloth can be used to polish the stainless steel face plate and 
strike plate as required. 
 

10. WARRANTY 
 

The  COBALT-mini  is  covered  with  a  manufacturers  12month  warranty  against  faulty  or  malfunctioning  parts, 
components or product. At the 

manufacturer’s discretion, either a replacement lock or affected part will be supplied 

to  remedy  the  fault  or  the  lock  can  be  returned 

at  the  customer’s  expense  to  the  manufacturer  for  repair. 

Mistreatment or ill-use of the lock may void the warranty. COBALT-mini is a trademark of BQT Solutions (SEA) Pte 
Limited. BQT Solutions (SEA) Pte Limited will not be liable for any direct, indirect, incidental or consequential loss 
or damage in any way related to this product. 
 

11. UPGRADE 
 

The  COBALT-mini  is  designed  by  BQT  Solutions  (SEA)  Pte  Limited  and  manufactured  by  BQT  Solutions  (NZ) 
Limited. BQT Solutions (SEA) Pte Limited reserves the right to upgrade or change this product without prior notice.  
For more information visit www.bqtsolutions.com 
 

Summary of Contents for COBALT-mini YD39M

Page 1: ...YD30M COBALT mini INSTALLATION AND OPERATING INSTRUCTIONS...

Page 2: ...T o 4 1 Mechanical o 4 2 Electrical 5 INSTALLATION o 5 1 Mortise Installation o 5 2 Surface installation 6 WIRING o 6 1 Fail Safe connection o 6 2 Fail Secure connection o 6 3 Jumper position 7 OPERAT...

Page 3: ...sition With the door secured and locked the COBALT mini can be given an unlock signal and it will instantly unlock If the door is loaded pre load when the unlock signal is given the COBALT mini will s...

Page 4: ...BQT Solutions SEA Pte Limited Page 3 3 DIMENSIONS 3 1 Lock 3 2 Strike Plate 3 3 Fitting Tab 3 4 Housing Available separately 3 5 Dress Plate Available separately...

Page 5: ...e door is approaching from the right then the bolt pin is at the bottom as indicated below 4 2 Electrical The first consideration is to establish where to run the wires and decide on what feedback is...

Page 6: ...the supplied fitting tabs can be used to secure the lock and strike plate in place The mortise behind the lock body needs to have enough space to accommodate the wiring 5 1 2 Wiring the lock Wires ar...

Page 7: ...determine exactly where the wiring will enter the housing and drill one or two 8mm holes through the housing wall Ensure the holes are on the housing face that goes against the wooden frame Push the...

Page 8: ...glass to give a clean finish The protective coating on the dress plate can be removed once it is in place 5 2 5 Fitting the strike plate into the housing The strike plate is placed into the housing a...

Page 9: ...Door Position Switch WHITE COM 6 1 Fail Safe Connection When wiring the COBALT mini the positive voltage is connected to RED negative is connected to BLACK and a switched positive voltage wire connec...

Page 10: ...ng as the door is open but will instantly re lock when voltage is applied to the BLUE wire and the door is closed In the event of a power failure voltage is removed from the BLUE wire and the COBALT m...

Page 11: ...t after initial power up is 250mA 12VDC and 200mA 24VDC 9 MAINTENANCE The COBALT mini has been lubricated at assembly and applying any other type of lubricant may void the warranty Removing the lock c...

Page 12: ...BQT Solutions SEA Pte Limited Page 11 NOTES Version 3 0...

Reviews: