TROUBLESHOOTING CHART – HONEYWELL V1 continued.
LED Status
Control Status
Probable Cause
Five flashes and three
second pause.
Temperature sensor
fault.
1. Damage to the temperature
wire.
2. Temperature sensor
resistance out of range.
3. Replace temperature sensor.
4. If temperature sensor
replacement does not
correct the problem; verify
control is not wet or
physically damaged.
5. Turn set point knob to "OFF"
position. Turn set point knob
to "PILOT" position and light
pilot.
6. Replace gas valve if five
flash error persists.
Six flashes and three
second pause.
Water leak detected by
accessory module (some
models).
Excessive amount of water in
drain pan/water dam.
Seven flashes and
three second pause.
Gas valve electronic fault
detected.
1. Verify control is not wet or
physically damaged.
2. Turn set point knob to "OFF"
position. Turn set point knob
to "PILOT" position and light
pilot.
3. Replace gas valve if seven
flash error persists.
Eight flashes and three
second pause.
False pilot flame present.
1. Pilot valve stuck in open
position.
2. Turn set point knob to "OFF"
position. Turn set point knob
to "PILOT" position and light
pilot.
3. Replace gas valve if eight
flash error persists.