THE FOLLOWING INSTRUCTIONS ARE FOR INSTALLATION OF:
GAS WATER HEATERS
SUITABLE FOR WATER (POTABLE) HEATING AND SPACE
HEATING
1. All piping components connected to this water heater for space heating
applications must be suitable for use with potable water. In
Massachusetts, space heating piping length
must not
exceed 50 feet.
2. Toxic chemicals, such as those used for boiler treatment,
must not
be
introduced into potable water used for space heating.
3. This water heater
must not
be connected to an existing heating system or
component(s) previously used with a non-potable water heating appliance.
4. When the system requires water for space heating at temperatures higher
than required for other uses, a means such as an ASSE approved mixing
valve shall be installed to temper the water for those uses in order to
reduce scald hazard potential.
Please refer to figure 8 and figure 9 for suggested piping arrangements.