9
Bradley Corporation
215-857 Rev. B; EN 97-1016
Bradley LavCare 500 Series Patient Care Module
Installation Instructions
Model LC500 L/F and L/W
Installation Instructions
continued . . .
Step 5: Install the countertop to the
cabinet
1. Apply a bead of silicone caulk (supplied
by installer) around the top edge of the
cabinet and between the countertop and
the wall (see Figure 9).
2. Set the countertop in place on the cabinet.
3. Clean up any excess caulk around the
edge of the countertop.
Step 6a: Install faucet (with wrist-
blade faucet valve) and connect
water supply
NOTE: On LC500 models with the foot valve
faucet, refer to step 6b found on page 10. On
LC500 models with the optional Futura
faucet, use installation instructions specifically
for the Futura faucet when installing the
faucet and making the electrical connections.
NOTE: To make supply connections easier,
remove the access panels first.
1. Place the faucet onto the countertop,
gently inserting the two faucet supply
shanks through the holes provided in the
lavatory bowl (see Figure 10).
2. Install the two washers provided onto
the supply shanks from beneath the
countertop. Secure the washers and the
faucet to the countertop with the two
wingnuts provided (see Figure 10).
3. Connect the hot and cold water supplies
to the faucets 1/2 NPT hot and cold
supply inlets (piping supplied by
installer) (see Figure 10).
4. Install the P-trap (supplied by installer)
to the sinks 1-1/4 O.D. drain pipe
5. Connect the P-trap to the 1-1/4 NPT
drain pipe from the wall (piping supplied
by installer).
Figure 9
Figure 10
COUNTERTOP
SILICONE CAULK
WINGNUT
COUNTERTOP
1/2 NPT
HOT INLET
1/2 NPT
COLD INLET
WASHER
LAVATORY
BOWL
Installation Instructions
continue . . .