Assemble and install bowl
WARNING:
To prevent serious injury and/or damage to
the bowl, move and position the bowl with
the assistance of another person and always
use appropriate lifting procedures.
WARNING:
Do not leave the bowl on the pedestal
unsupported, as it may fall and cause
personal injury or damage to property.
NOTE!
Discard rubber gasket included with drain
spud. It cannot be used in this application.
INSTALL TWO 3/8" WALL ANCHORS (SUPPLIED BY INSTALLER)
WHICH WILL BE USED TO MOUNT THE BOWL TO WALL (SEE
ROUGH-INS ON PAGE 4).
A
WITH THE HELP OF AN ASSISTANT, CAREFULLY LIFT THE BOWL ONTO THE PEDESTAL FRAME USING
APPROPRIATE LIFTING PROCEDURES. ENSURE BOWL REMAINS 3 – 4 INCHES FROM THE WALL.
B
INSTALL THE TWO WALL ANCHOR BRACKETS TO THE BACK OF THE BOWL USING THE 3/8"- 16 X 1-1/2" HEX-HEAD BOLTS, 13/32"
I.D. PLAIN WASHERS, ANCHOR PLATES, 3/8" I.D. LOCKWASHERS, AND 3/8"- 16 HEX NUTS PROVIDED.
C
SLIDE THE BOWL BACK TO THE WALL AND SECURE THE BOWL’S WALL BRACKETS TO THE WALL ANCHORS WITH TWO 3/8" BOLTS
AND WASHERS (SUPPLIED BY INSTALLER).
D
FASTEN THE BOWL TO THE UPPER BRACKET ON THE PEDESTAL ASSEMBLY WITH THE TWO 1/4"- 20 X 1/2" ROUND-HEAD SCREWS
AND 5/16" I.D. WASHERS SUPPLIED.
E
INSTALL THE DRAIN SPUD IN THE BOWL USING PLUMBER’S PUTTY.
F
FROM BENEATH BOWL, THREAD THE SPUD WASHER AND SPUD LOCKNUT ONTO THE DRAIN SPUD AND TIGHTEN THE LOCKNUT
AGAINST THE BOWL.
G
INSTALL STRAINER IN THE BOWL DRAIN USING THE TWO #10-24 X 1/2" FLAT SOCKET HEAD SCREWS SUPPLIED.
H
CONNECT THE DRAIN TRAP (SUPPLIED BY INSTALLER) TO THE DRAIN SPUD AND DRAIN LINE.
I
5/16" I.D. PLAIN
WASHERS
1/4-20 X 1/2"
SCREW
PEDESTAL
BOTTOM
OF
BOWL
UPPER
BRACKET
Washer
#10-24 x 1/2"
Screw for
Strainer
Drain
Spud
Spud
Spud
Dome
Strainer
Discard this
washer; it is not
used on
washfountains
Washfountain
Bowl
Locknut
Drain Assembly