SN2005/TT
Installation
6
10/20/2014
Bradley
• 215-1760 Rev. L; ECN 14-00-007
3
Make Electrical Connections
WARNING! Your Sentry Washfountain MUST be connected to 24 VAC transformer provided.
Connection to 110 VAC will result in damage to the electronics and could result in personal
injury. Refer to Instruction Sheet 215-1503 for more information.
STOP!!! If installing optional Shroud/Slip Ring or Towel Dispensers,
complete those installations before proceeding to Step 4 (see next page).
24 VAC from transformer .
Attach minimum 18-gauge
wires (supplied by installer) to
transformer screw terminals
using 1/4" Quick-Connects .
Button
(Yellow)
4
Button (Green)
2
Button (Red)
1
Black
Brown
Top
Gray
Green
Transformer
(269-645)
Red Supply
Tube
Green Supply Tube
Black Supply Tube
Compression Nut
Navigator
Mixing Valve
or Tempered
Line
Adaptor
Terminal Block
(269-1311)
1
2
3
Black
Red
Top
Yellow Supply Tube
4
Button (Black)
3
Black
Red
Brown
Black
Button
(Clear)
4
5
Gray
Green
Clear Supply Tube