Adjusting the Temperature
CAUTION: This valve is NOT factory preset. Upon installation, the temperature of
this valve must be checked and adjusted to ensure delivery of a safe
water temperature. Water in excess of 110°F (43°C) may cause scalding.
Temperature
Adjustment Stem
Temperature Locking
Nut
B
C
Shut the hot water inlet off by closing the hot
water stop-strainer-check valve. While the
hot water supply is turned off, check to make
sure the cold water flow is reduced. If the
cold water is reduced properly, reopen the
hot water supply.
Shut the cold water inlet off by closing the
cold water stop-strainer-check valve. While
the cold water supply is off, check to make
sure that the hot water flow has shut down.
A
Check the temperature when
approximately 1.0 GPM water flow is
reached and adjust if necessary (the range
of the valve is 95°F–115°F (35°C–43°C).
To adjust the temperature:
• Loosen temperature locking nut with
wrench.
• Using a blade screwdriver, turn the
adjustment stem counterclockwise to
increase the temperature or clockwise
to decrease the temperature
• Once desired temperature has been
reached, tighten lock nut to prevent
change in temperature.