background image

1

SEELEY INTERNATIONAL –

 

HOME OWNER’S MANUAL

GENERAL

Congratulations on choosing a new Evaporative Cooler for your home.

Your cooler is built from the highest quality materials and engineered to 

provide many years of economical, trouble free cooling.

Please take a few minutes to read these instructions so you have a full 

understanding of how to operate your cooler using your Spectrolink 

Comfort Control.

Your installer should demonstrate the features and procedures  set out in 

these instructions. The installer should also provide you with a Model and 

Serial number which can be filled out below.

EFFECTIVE COOLING

To provide efficient cooling or ventilation the building must have sufficient 

exhaust openings to the outdoors in the form of doors, windows or other 

vents. To assist air circulation, open windows or doors that are furthest 

from the outlet vent in each room. In every room that has an outlet vent, 

provide an exhaust opening 2 to 2.5 times the outlet vent size.

Where the design of the building prevents adequate exhaust, 

consideration should be given to the provision of mechanical extraction 

such as an exhaust fan.

Model No: ____________________ Serial No: _____________________ 

EVAPORATIVE COOLING

Summary of Contents for Spectrolink

Page 1: ... 623528m Version 23 09 14 English with Spectrolink Comfort Control HOME OWNER S MANUAL DUCTED GAS HEATER ...

Page 2: ...parts or is subject to wear and tear it is VERY IMPORTANT that you maintain your ducted gas heater and have it regularly serviced It is a condition of warranty cover for your ducted gas heater that you comply with all of the maintenance and service requirements set out in this Owner s Manual Compliance with these requirements will prolong the life of your ducted gas heater Further it is also a con...

Page 3: ...mar Breezair or Coolair evaporative cooler or operation of a refrigerated cooling system HEATER OPERATION CONTENTS PAGE SECTION Quick Start MANUAL Operation 1 Setting the Time and Day 1 Button Functions 2 Display Features 3 MANUAL Mode Operation 5 AUTO Mode Operation 6 Setting the AUTO Program Single SCC 7 Setting the AUTO Program Multiple SCC s 9 Adjusting the Fan Speed 11 Using the Fan Only Feat...

Page 4: ...mperature setting by pressing the UP arrow button until the set temperature is as required SETTING THE TIME AND DAY 1 Press the ON OFF button to turn the SCC OFF 2 With the SCC turned off press and hold the SET button for 3 seconds SET and the time display will flash 3 Press the UP or DOWN arrow button to adjust to the current time ensure that AM PM is correct Hold button for rapid adjustment 4 Pr...

Page 5: ... and automatic operating modes SET Press to lock in adjusted parameters or to enter clock setting mode press with SCC off or program setting mode press with SCC on AC MODE Press to toggle between HEAT and COOL mode UP ARROW Press to increase value in setting modes or to increase temperature set point FAN Press to enter fan speed adjustment mode 4 5 star heaters with single SCC only COOL VENT Press...

Page 6: ...5 seconds Temperature is not displayed in evaporative cooling mode Evaporative or refrigerated air conditioner where installed is operating SCC is in MANUAL operation mode MAN SCC is in AUTOMATIC operation mode AUTO WAIT and ON are displayed flashing at the start of a heating or evaporative cooling cycle WAIT COOL mode is selected on SCC COOL HEAT mode is selected on SCC HEAT SET is displayed flas...

Page 7: ...enabled zones can be displayed A zone number displayed indicates that a zone is on Battery symbol is displayed when the power to the heater is off or the SCC is disconnected Current time and day settings will be retained for approximately 1 hour Note This SCC is hard wired to the heater and does not use batteries Service call required Contact your local Braemar dealer or contact Braemar Service on...

Page 8: ...inue to run until the heater has cooled sufficiently Adjusting the Room Temperature 1 Increase set temperature Press the UP arrow to increase set temperature by 1o C 2 Decrease set temperature Press the DOWN arrow to decrease set temperature by 1o C Adjusting the Fan Speed 1 With the SCC on press and hold the FAN button for 3 seconds the fan speed and fan symbol will flash 2 Press the up or down a...

Page 9: ...e SCC will automatically advance to the next time period and operate according to the set temperature for the new time period Turning the Heater OFF 1 Press the ON OFF button 2 The display will revert to OFF mode 3 The room fan will continue to run until the heater has cooled sufficiently Adjusting the Room Temperature 1 The set temperature can be temporarily adjusted while operating in AUTO mode ...

Page 10: ...e of 15ºC 7 SETTING THE AUTO PROGRAM SINGLE SCC In a SINGLE SCC system the SCC can be programmed to operate the heater over the 4 time periods of WAKE AWAY HOME and SLEEP For each of these time periods you can set the following START TIME SET TEMPERATURE ZONES HEATED where zones have been installed 4 5 6 star only FAN SPEED Use the table below to record your program settings The table includes fac...

Page 11: ...iod temperature 1 Press UP or DOWN arrow buttons to adjust to required set temperature for displayed time period 2 Press SET when required temperature is displayed Set WAKE period zones where fitted 1 Where zones have been fitted and enabled by theinstaller when setting up the system zones can be set to be either on or off for the displayed time period 2 Press ZONE buttons 1 2 3 4 to turn zones on...

Page 12: ...zone The fan speed is automatically adjusted to suit zones in operation at any time based on individual zone fan speeds set by your installer Use the table below to record your program settings The table includes factory default program settings in brackets PROGRAM SETTINGS ZONE 1 ZONE 2 ZONE 3 ZONE 4 Time ON Temp o C Time ON Temp o C Time ON Temp o C Time ON Temp o C Time period 6 00am HEAT WAKE ...

Page 13: ...tart time for displayed time period 2 Ensure that AM or PM is correct 3 Press SET when the required start time is displayed Set WAKE period temperature 1 Press UP or DOWN arrow buttons to adjust to required set temperature for displayed time period 2 Press the ON OFF button on the Master SCC The Master SCC must be ON to enable Slave controls to be turned ON 3 Press the ON OFF button on SCC you wis...

Page 14: ...s to adjust to the required maximum gas rate then press SET maximum fan speed will also be adjusted automatically 4 Important note this feature should only be used in milder weather and should be returned to 100 when full heating capacity is required USING THE FAN ONLY FEATURE Single SCC Systems 1 Turn the SCC OFF press ON OFF button if required 2 Press and hold the FAN button for 3 seconds the he...

Page 15: ... and on the following page If you are unable to reset the fault and are requesting a service call please quote the displayed fault code number this may enable the fault to be fixed over the phone Resetting a Fault If RESET is flashing and a fault code is displayed Open the SCC door and press RESET once this acknowledges the fault and turns the SCC and heater off Press RESET again to send a RESET s...

Page 16: ...press AC MODE button to change to HEAT mode if required If operating in MANUAL mode check that HOME is selected on SCC press HOME AWAY button if required Check that doors and windows are closed Check that the time and day displayed are correct Check that AM PM is correct in the AUTO program settings Check time temperature zones and fan speed settings in the AUTO program TROUBLESHOOTING cont PROBLE...

Page 17: ...kPa kPa kPa kPa kPa kPa kPa kPa Action taken key Inspected and working correctly no action required A Adjustment of part C Cleaning of part R Replaced part To owner user please note that as explained in your Warranty Card installation is not covered by the warranty for example ductwork the return air grille and filter and electrical and gas connections to the ducted gas heater However we still req...

Page 18: ...15 Spectrolink Comfort Control NOTES ...

Page 19: ...HOME OWNER S MANUAL 623528m Version 23 09 14 English Spectrolink Comfort Control Cooling ...

Page 20: ... Season Maintenance 7 Troubleshooting 8 Notes 9 Refrigerated Cooling PAGE SECTION General R1 Selecting COOL Mode R1 Setting the Time and Day R1 Button Functions R2 MANUAL Mode Operation R3 AUTO Mode Operation R4 Setting AUTO Progam R5 Fan Only Operation R5 Troubleshooting R6 Notes R7 Please note There are separate Owner s Manuals for the evaporative cooler and for the refrigerated cooling unit You...

Page 21: ...taller should also provide you with a Model and Serial number which can be filled out below EFFECTIVE COOLING To provide efficient cooling or ventilation the building must have sufficient exhaust openings to the outdoors in the form of doors windows or other vents To assist air circulation open windows or doors that are furthest from the outlet vent in each room In every room that has an outlet ve...

Page 22: ... door 2 Press the AC MODE button to switch between HEAT and COOL mode Setting the Time and Day 1 Press the ON OFF button to turn the SCC OFF 2 With the SCC turned off press and hold the SET button for 3 seconds SET and the TIME display will flash 3 Press the UP or DOWN arrow button to adjust to the current time ensure that AM PM is correct Hold button for rapid adjustment 4 Press the SET button wh...

Page 23: ... used in evaporative cooling mode MAN AUTO Press to toggle between manual and automatic operating modes SET With SCC off Press once to enter timer setting mode Press and hold to enter clock setting mode AC MODE Press to toggle between HEAT and COOL mode UP ARROW Press to make adjustments in timer and time setting modes FAN Not used for evaporative cooler operation COOL VENT Press to turn pump on o...

Page 24: ...arrow buttons to increase or decrease the fan speed Turning the Pump On or Off 1 Press the COOL VENT button to turn the pump on or off 2 Pump ON evaporative cooling mode 3 Pump OFF ventilation only mode 4 With the pump turned on the SCC will flash WAIT at the start of a cooling cycle while waiting for the cooler tank to fill with water and to pre wet the cooler pads The snowflake symbol is display...

Page 25: ...djust to required STOP time then press SET Press UP or DOWN arrows to adjust to required START time then press SET Press UP or DOWN arrows to adjust to required STOP time then press SET When operating in AUTO mode the user controls the cooling output The pump and fan speed are controlled automatically MAN ON COOL AUTO ON COOL MAN ON COOL MAN COOL OFF AUTO ON COOL AUTO COOL OFF TIMED START AND STOP...

Page 26: ...off for a continuous 72 hours 3 days or A manual drain can be initiated at any time by pressing the UP and DOWN arrow buttons simultaneously with the SCC off and door closed The display will show dr to confirm the operation has activated During the drain operation all buttons are in operative When the cooler is re started there will be a delay while the cooler tank is re filled with fresh water WA...

Page 27: ...ovided for you to pass on to your service agent if required to ensure that the correct maintenance is carried out End of Season Maintenance 1 Turn off power to cooler 2 Turn off water to cooler 3 Remove the pad frame assemblies take care not to damage the pads 4 Turn off power switch inside the cooler 5 Check and clean the lid water channels 6 If fitted unclip and remove the bleed system Allow wat...

Page 28: ...quate cooling An operational fault has been detected by the cooler s in built diagnostic software Check the following Ensure that the water supply and power have been turned on to the cooler Check the cooler drain pipe is not blocked Record the number displayed on the screen this will be where the time is usually displayed If required call Service on 1300 650 644 and quote the number displayed on ...

Page 29: ...9 SEELEY INTERNATIONAL HOME OWNER S MANUAL NOTES ...

Page 30: ...n of this manual The time and day can be set with either HEAT or COOL mode selected Your refrigerated cooling system has been installed in conjuction with your Braemar Ecostar gas ducted heater The cooling system utilises the heater fan and uses the same ducting as the heater to distribute cool air throughout your home Your installer should demonstrate the features and procedures set out in these ...

Page 31: ...ing modes SET Press to lock in adjusted parameters or to enter clock setting mode press with SCC off or program setting mode press with SCC on AC MODE Press to toggle between HEAT and COOL mode UP ARROW Press to increase value in setting modes or to increase temperature set point FAN Press and hold SCC off to enter fan only operation mode COOL VENT Not used in refrigerated cooling mode ZONE 1 2 3 ...

Page 32: ... in 2 minute delay to prevent the compressor from re starting within less than 2 minutes of last turning off this is to prevent damage to the compressor Turning the Cooler OFF 1 Press the ON OFF button The display will revert to OFF mode The room fan and compressor will turn off immediately Adjusting the Room Temperature 1 Decrease set temperature Press the DOWN arrow to decrease set temperature b...

Page 33: ...e set temperature for the new time period The SCC has a built in 2 minute delay to prevent the compressor from re starting within less than 2 minutes of last turning off this is to prevent damage to the compressor Turning the Cooler OFF 1 Press the ON OFF button The display will revert to OFF mode The room fan and compressor will turn off immediately Adjusting the Room Temperature The set temperat...

Page 34: ... button for 3 seconds the heater fan will start and increase to its maximum speed 3 To get air flow to zones where fitted press the corresponding zone button The fan speed is not adjustable in FAN only mode 4 Press the ON OFF button to turn the fan off Multiple SCC Systems 1 Turn the Master SCC OFF press ON OFF button if required 2 Press and hold the FAN button on the Master SCC for 3 seconds the ...

Page 35: ... unit manufacturer TROUBLESHOOTING PROBLEM House is not heating effectively PROBLEM There is airflow from the outlets but it is not cool If it is accessible check that power is turned on to the heater Check that the SCC is set to COOL mode press AC MODE button to change to COOL mode if required Check that SCC is set to required temperature decrease if required Temperature set point must be less th...

Page 36: ...R7 Spectrolink Comfort Control NOTES ...

Reviews: