The Service/Diagnostic menu
Main Menu - Warning - Service/Diagnostic
When entering this menu choice, a warning window will appear.
The purpose of this warning is make the user aware that the safety
switches on the cover is now disabled. This is done to make it possible
to run smaller tests during service.
Please take care for the rotating parts!
The Printer may unexpectedly be started by other users!
To make sure you have absolutely control when doing service with the power connected, please dis-
connect the computer cables (Ethernet and USB).
Print Test Pattern:
Main Menu - Warning - Service/Diagnostic - Warning -
Print Test Pattern
When entering this menu choice, a warning window will appear.
This is to make the user aware that print jobs from the computer will
not be printed as long as you are in this sub-menu.
- X pattern.
Will print dots in a x pattern across the sheet,
useful when searching for missing dots.
- Full cell, single sided.
Prints all six dots on all characters on one side of the sheet,
useful for dot quality tests.
- Full cell, both sides.
Prints all six dots on all characters on both sides of the sheet,
useful for testing the paper quality.
- O/Ø pattern.
Prints a test pattern made of dot 1,3,5 and 2,4,6, single-sided, useful when searching for extra dots.
BRAILLO
l
B 650 SW
40
Summary of Contents for 650 SW
Page 1: ...BRAILLO L NORWAY FOR BETTER BRAILLE AND MORE User s Guide BRAILLO 650 SW Rev January 2018 ...
Page 2: ... 2018 Braillo Norway AS ...
Page 4: ...BRAILLO l B 650 SW 4 ...
Page 96: ...Frame complete BRAILLO l B 650 SW 96 ...
Page 123: ...BRAILLO l B 650 SW 123 115 cm 77 cm 112 cm 8 5 Measurements All measurements in centimetres ...
Page 124: ...9 GENERAL INFORMATION 9 1 Declaration of conformity BRAILLO l B 650 SW 124 ...