Malfunction 

Possible Cause

Remedy

The compressor does not start imme-
diately after changing the tempera-
ture setting.

This is normal, no error has occurred. The compressor starts after a period of time.

Water drain hole is blocked.

See the "Cleaning and Care" section.

Water on the floor or on storage
shelves.

Changing the light bulb

Warning!

There is a risk of electric shocks! Before changing the light bulb, switch off the appliance and

unplug it, or pull the fuse or the circuit breaker.
Light bulb data: 220-240 V, max. 15 W
To switch off the appliance, turn the temperature regulator to position "0".
Unplug the mains plug.
To change the light bulb, undo the screw.
Press the light bulb cover as shown and slide it backwards.
Change the defective light bulb.
Refit the light bulb cover and the screw.
Put the refrigerator back into operation.

AEG65

Noises during Operation

The following noises are characteristic of refrigeration appliances: 

Clicks

Whenever the compressor switches on or off, a click can be heard.

Humming

As soon as the compressor is in operation, you can hear it humming.

Bubbling/

When refrigerant flows into thin tubes, you can hear bubbling or splashing noises. Even 

Splashing

after the compressor has been switched off, this noise can be heard for a short time.

Summary of Contents for TCA 160 WE

Page 1: ...Gebrauchsanweisung Tisch K hlautomat Mode d emploi R frig rateur automa tique table top Gebruiksaanwijzing Tafelmodel koelkast Operating Instructions Automatic refrigerator TCA 160 WE 2222632 34...

Page 2: ...e are stressed with a warning triangle and or with signal words Warning Caution Attention Please observe the following carefully This symbol guides you step by step in the operation of the appliance S...

Page 3: ...48 Description of the appliance 48 View of the appliance 48 Starting up and temperature regulation 49 Interior Accessories 49 Storage shelves wire trays 49 Variable door interior 49 VARIO glass storag...

Page 4: ...and sources of ignition thoroughly ventilate the room in which the appliance is situated Safety of children Packaging e g wraps polystyrene can be dangerous for children There is a risk of suffocation...

Page 5: ...The refrigerant circuit especially the heat exchanger at the back of the appliance must not be dam aged Information concerning collection schedules or locations can be obtained from your local Council...

Page 6: ...ther refrigerator or freezer a clearance of 5 cm at the sides is required in order to prevent the formation of condensation on the outside of the appliance Your refrigerator needs air The refrigeratin...

Page 7: ...prop it securely Unscrew the door hinge screws K and remove the hinge pin bracket 1 Open the door a little way and take it out downwards Unscrew the upper pin A and screw it into place on the opposit...

Page 8: ...iance is installed under a continuous work top the plug socket should be provided as shown Alternatively a concealed spur socket fitted with a 13 A fuse may be fitted If the socket is not accessible o...

Page 9: ...or is not running see also Defrosting section The result is the build up of a thick layer of frost on the fridge rear wall If this happens turn the temperature regulator back to a warmer setting posit...

Page 10: ...re suited for packaging Polyethylene airtight bags and wraps Plastic containers with lids Special plastic covers with elastic aluminium foil Defrosting The fridge defrosts automatically The rear wall...

Page 11: ...onents danger of electrical shock Hot vapours can lead to the damage of plastic parts The appliance must be dry before it is placed back into service Important Ethereal oils and organic solvents can a...

Page 12: ...properly adjusted Please look in the Initial Start Up section Door was open for an extended peri od Open the door only as long as necessary A large quantity of warm food was placed in the appliance wi...

Page 13: ...urred The compressor starts after a period of time Water drain hole is blocked See the Cleaning and Care section Water on the floor or on storage shelves Changing the light bulb Warning There is a ris...

Page 14: ...om the food sto red in the fridge or freezer can cause the refrigerant to boil and vaporise Closed circulation system that contains the refrigerant The refrigerant circuit compri ses primarily of an e...

Page 15: ......

Page 16: ......

Reviews: