FDU-160i
FDU-160i Frequency Distribution Unit – Operation and Maintenance Manual
P/N 900000136 REV B
18
6
Alternate Access
If the unit is in an area where it cannot be accessed over the network, but physical access
to the device is still possible, the FDU-160i can still be accessed and controlled via RS-232
over the serial port.
6.1.1
User Commands and Responses
The FDU160i Serial port (115200,8,1,1,no parity) provides status and setting data on
request from the user.
The user can obtain information from the FDU160i by sending HELP command
terminated by CR. The FDU160i will display the HELP MENU as below:
-----------------------------------------------------------------------------------------------
FDU160i System Setup - (925000120) 1.01.05 Jul 9 2013
SN# 36770 - Hardware Ver: A
-----------------------------------------------------------------------------------------------
COMMAND Description
----------------------------------------------------------------------------------------------
HELP
Show this screen
IPADDR
IP Address (set to 0.0.0.0 to enable DHCP) (192.168.1.121)
IPMASK
IP Mask (255.255.255.0)
IPGATEWAY
IP Gateway (192.168.1.1)
MACADDR
MAC Address (00-21-34-00-02-EB)
FACT
Factory Reset to Defaults Setting
RESET
Reset System
Enter a menu command:
The FDU160i user commands are described in the table below.
COMMAND
FUNCTION
COMMENTS
HELP
Show Help
Show Help Menu
Example:
HELP<CR>
Displays the above Help Menu.
IPADDR
Set IP Address
Setthe IP Address (decimal number) IP4, IP3, IP2,
IP1 and Store into NVM.
Example: