Page 10
Floor Level and Bridge Plate Adjustments
Bridge Plate Cam Adjustment
4. Remove the cam securement nut
(Figure D). Partially fold bridge plate
to take pressure off the cam and ease
cam bolt removal.
5. Carefully unfold bridge plate to rest on
YHKLFOHÁRRU
8VLQJGLPHQVLRQWDNHQLQVWHSUH
-
place cam securement bolt in the hole
that corresponds to the height dimen-
sions in table below.
1RWLFH$SSUR[LPDWHGLPHQVLRQVLQ
below table. Dimensions between list-
ings - try two nearest holes for opti-
mum setting.
7. Secure cam bolt with nut as shown in
Figure D. Tighten securely.
8. Switch on lift main power and raise the
SODWIRUPWRÁRRUOHYHOWRYHULI\FRUUHFW
position of bridge plate.
Cam Hole #
Height (in)
Height (cm)
1*
11.5
29
2*
15
38
3
18.5
47
4
19
48
5
22
56
6
23.5
60
7
24.5
62
8
26
66
9
27.5
70
10
29
74
*Not used without kit 75400ROAS
1
2
3
4
7
8
9
10
5
6
Figure D
Cam Hole Number Layout
D
Measure from top
RIUROOLQJKRUL]RQWDO
carriage arm to the
bottom of platform.
See table below.
Cam Bolt
Cam
Cam Hole Selection Table
Nut
3.8 cm -6.4 cm
(1 1/2
" -