Page 46
Maintenance and Lubrication Schedule
Perform all procedures listed in previous section also
Resecure, replace or correct as needed
Use Braun 32840-QT hydraulic
fl
uid (Exxon
®
Uni-
vis HVI 26). Do not mix with Dextron III or other
hydraulic
fl
uids. Check
fl
uid level with platform
lowered fully. Fill to maximum
fl
uid level indicated
on reservoir (speci
fi
ed on decal). Do not over
fi
ll.
If
fl
uid level decal is not present - measure 1-3/8"
from the
fi
ll port to locate
fl
uid level.
Tighten, repair or replace if needed.
Replace if needed.
Tighten or replace if needed.
Replace damaged parts and resecure as needed.
Apply synthetic grease during reassembly proce-
dures.
Replace if needed.
Inspect cotter pins on platform pivot pin (2)
Hydraulic Fluid (Pump) - Check level. Note: Fluid
should be changed if there is visible contamination.
Inspect the hydraulic system (cylinder, hoses,
fi
t-
tings, seals, etc.) for leaks if
fl
uid level is low.
Inspect cylinders,
fi
ttings and hydraulic connections
for wear, damage or leaks
Inspect parallel arms, bearings and pivot pins for
visible wear or damage
Inspect parallel arm pivot pin mounting bolts (8)
Inspect platform pivot pins, bearings and vertical
arms for wear, damage and positive securement
Inspect inner/outer fold arms, saddle, saddle sup-
port and associated pivot pins and bearings for
visible wear or damage
4500
Cycles
continued