background image

Page 23

Lift Operating Instructions

Lift Power

On/Off Switch

Power

Indicator

Light

Before lift operation, park the vehicle on a level 

surface, away from traffic.  Place the vehicle 

transmission in “Park” and engage the parking 

brake.  Vehicle engine must be running.  

Lift Operating Instructions address operation of 

the lift only.  

Vehicle Doors and Vehicle Interlocks:  Transit 

vehicle lift doors and interlocks vary.  Procedures 

to operate them vary also.  Lift operators 

(attendants) must become familiar with the vehicle 

lift access door system and vehicle interlock(s).  

Manual Door(s):  Open manual doors fully and 

secure in full open position before operating the 

lift.  

Do not operate the lift if you suspect lift damage, 

wear, or any abnormal condition.  Refer to the 

Manual Operating Instructions to manually operate 

lift.

Hand-held

Pendant Control

36514

Lift Power ON/OFF Switch:  

This switch must be 

in the ON position in order to activate the lift.  The 

green Power Indicator Light illuminates to signal 

power to the lift.

      UP:  

From ground level, the UP function will   

      raise (rotate) the roll stop to the vertical 

position.  The platform then raises to floor level 

position.

      DOWN:  From floor level, 

the DOWN function 

      lowers the platform to ground level and then 

unfolds (lowers) the roll stop to the ramp (horizon-

tal) position.

Control Switch Functions:

Hand-held Pendant Control:  

The hand-held 

attendant’s pendant control is equipped with two 

rocker switches.  When there is power to the lift, 

the lift function labels illuminate to identify the 

functions.

         

FOLD:  From floor level, the FOLD function 

         folds the platform inward to the stowed

position.

         

UNFOLD:

  From stowed position, the 

         UNFOLD function unfolds the platform out-

ward to the floor position.

Note:  If any functions do not occur as 

described, discontinue lift use immediately. 

 

Summary of Contents for L1100IB4061RP-2

Page 1: ...1 Rev A November 2015 Original Instructions International Owner Manual ISO 9001 2008 www braunability com international 631 West 11th Street Winamac IN 46996 USA Phone 1 574 946 6153 Fax 1 574 946 467...

Page 2: ...ou again for your business and enjoy your independence Sincerely The BraunAbility Employee Family OWNER S WARRANTY REGISTRATION War Card 07 ai PURCHASED FROM DATE INSTALLED NAME ADDRESS CITY TELEPHONE...

Page 3: ...3 Connect Interlocks 14 Lift Operating Instruction Decal 14 Platform Angle Adjustment 15 Tower Microswitch Adjustment 16 17 Installer Verification 18 19 Lift Operation Safety 20 22 Lift Operating Inst...

Page 4: ...ock do not attempt to open the enclosure or gain access to areas where you are not instructed to do so Refer servicing to qualified service personnel only This symbol indicates that a condition where...

Page 5: ...injury and or property damage WARNING WARNING Read this manual supplement s and lift posted operating instructions decals before performing installation operation or service procedures Use appropriate...

Page 6: ...r electric shock do not attempt to open the enclosure or gain access to areas where you are not instructed to do so Refer servicing to qualified service personnel only This symbol indicates that a con...

Page 7: ...lectrical storms or similar electrical phenomena Use caution when operating this equipment in severe weather or environmental conditions fog rain snow ice dust etc Discontinue lift use immediately if...

Page 8: ...ols Turn powered electric wheelchairs off when on lift platform Press the DOWN switch until the entire platform rests on ground level lowered fully and the roll stop is fully unfolded ramp position be...

Page 9: ...65 C Relative Humidity This equipment will operate correctly within an environment at 50 RH at 40 C Altitude This equipment will operate correctly up to 1000 m above mean sea level Sound Pressure Leve...

Page 10: ...etailed in this manual Any use of equipment other than instructed in this manual is prohibited Pump Module Rear Hand Held Pendant Control Base Plate Base Plate Cover Top Parallel Arm 2 Adjustable Quie...

Page 11: ...and the door or wall See Figure D Lift Tite Latches When checking ve hicle wall clearance allow the lift to drift fully into the Lift Tite latches to ensure clearance should drift occur See Figure F U...

Page 12: ...ns It is not permissible for the base plate to overhang the step well Base plate support must be constructed in the step well for lift support The structure must be level with the existing floor and o...

Page 13: ...n detail below Mounting Bolt Torque Tar get 40 Nm Check for obstruc tions such as gas lines wires exhaust etc before drilling or cutting Failure to do so may result in serious bodily injury and or pro...

Page 14: ...et Route cables clear of exhaust other hot areas and moving parts 4 Connect ground and power cables Lift Installation Attach Power and Ground Cables Figure I Vehicle Battery Positive Cable Install in...

Page 15: ...gure J Vehicle Battery Ground Cable A 4 gauge 21 1mm2 ground cable must be connected from vehicle battery negative post to the same vehicle framing member the pump ground cable is attached to See Figu...

Page 16: ...S Install 32638A in cavity 5 LIFT NOT STOWED 9 LIFT STOWED VEHICLE SECURE SIGNAL Grey Red LIFT SIGNAL Yellow Light Blue PUMP MODULE CONNECTOR J21 6 5 4 3 2 1 SIGNAL DEFINITION NO 9 COND WIRE CODE 7 VE...

Page 17: ...tion of vehicle of vehicle Heel Ground Level Outboard roll stop must unfold flly Platform heel must lower fully Outboard Roll Stop Floor level Wedges option Figure C 2 1 Adjustment Procedure Platform...

Page 18: ...m saddle and the lower parallel arm See Photo B Tower 2 Up Switch Adjustment Floor Position from Below Floor 1 Lower platform a minimum of 15 25 cm below floor level position using the manual hand pum...

Page 19: ...croswitch inside the lift tower see Photo D Turn the switch adjust ment screw in or out as needed until the radius of the microswitch blade rides on the apex of the activation plate 3 Verify proper ad...

Page 20: ...period Verify that the vertical drift of the platform between the two measurements has not exceeded 15 mm Verify that the angular drift of the platform between the two measurements has not exceeded 2...

Page 21: ...Access relief valve see illustration below Loosen 9 16 hex nut on the relief valve adjustment screw do not remove hex nut 6 Turn adjustment screw clockwise 1 8 turn 7 Press UP switch and verify lift...

Page 22: ...or electric shock do not attempt to open the enclosure or gain access to areas where you are not instructed to do so Refer servicing to qualified service personnel only This symbol indicates that a co...

Page 23: ...electrical storms or similar electrical phenomena Use caution when operating this equipment in severe weather or environmental conditions fog rain snow ice dust etc Discontinue lift use immediately if...

Page 24: ...rols Turn powered electric wheelchairs off when on lift platform Press the DOWN switch until the entire platform rests on ground level lowered fully and the roll stop is fully unfolded ramp position b...

Page 25: ...rate lift Hand held Pendant Control 36514 Lift Power ON OFF Switch This switch must be in the ON position in order to activate the lift The green Power Indicator Light illuminates to signal power to t...

Page 26: ...ee Photo C Release switch 3 Unlock wheelchair brakes and unload passenger from platform OPEN DOOR S AND SECURE Lift Operating Instructions TO UNFOLD PLATFORM Stand clear and press the UNFOLD switch un...

Page 27: ...st be fully unfolded ramp position until the entire wheelchair or standee has crossed the roll stop See Photos E and F Notice Passenger must be positioned fully inside yellow boundaries J I 2 Press UP...

Page 28: ...2 Nm seats stops O P E N C L O S E AI B P Valve 1 30 92 O P E N C L O S E approximate 1 5 mm intervals Valve Tightening Specification Once valve seats stops tighten 2 to 3 Nm as shown Notice Close ba...

Page 29: ...lease valve and turn counterclockwise open 1 4 turn only until the platform reaches ground level and the roll stop unfolds See Photo C Down To Lower Using hand pump handle a Place slotted end of pump...

Page 30: ...ncy Stop E Stop Operating Instructions To Activate E Stop Push E Stop button down To Reset E Stop 1 Turn lift power OFF 2 Pull E Stop button up 3 Turn lift power ON Lift Pump Module E Stop Button Lift...

Page 31: ...and the surrounding area before applying lubricants Clean only with mild detergent and water Do not clean with solvents Allow the lift to dry thoroughly and apply lubricants as specified after every...

Page 32: ...aring 16 LO Lift Tite Latches Pivot Points 2 LO Lift Tite Latch Dampening Spring 2 springs 4 Points LO Saddle Support Bearings 8 LO Outer Fold Arm Cam Followers 4 LO Inner Outer Fold Arm Contact Area...

Page 33: ...ght Grease to both sides of slot See Lubrication Diagram Apply Light Oil See Lubrication Diagram Apply Light Oil See Lubrication Diagram Apply Light Oil See Lubrication Diagram Resecure replace damage...

Page 34: ...e lever bearings 2 Bridge plate lever slot 2 Saddle support bearings 8 Inner fold arm roller pin bearings 4 Inner fold arm cam followers 4 Parallel arm pivot pin bearings 16 Handrail pivot pin bearing...

Page 35: ...or replace if needed Tighten repair or replace if needed Replace if needed Tighten or replace if needed Replace damaged parts and resecure as needed Apply Light Grease during reassembly procedures Re...

Page 36: ...ubrication Schedule Apply Door Ease or replace if needed See Lubrication Diagram Resecure or replace if needed Resecure repair or replace if needed Check to see that the lift is securely anchored to t...

Page 37: ...nery Directive We hereby certify that the machinery described above conforms with the essential health and safety requirements of Council Directive 2006 42 EC on the approximation of the laws of the M...

Page 38: ...g to EN ISO 11204 Appendix A Measurements were made at a height of 1 5 m and 1 m from the Operator Position and Bystander positions 4 dB A The difference between the extraneous noise level and the sou...

Page 39: ...dapt se AUTOADAPT UK LTD Unit 1 Windsor Industrial Estate Rupert Street Aston Birmingham B7 4PR UK Phone 44 0 121 33 35 170 E mail contact autoadapt co uk Dual Parallel Arm Hydraulic Lift System Centu...

Page 40: ...ons descriptions and specifications in this manual are based on the latest product information available at the time of publication The Braun Corporation reserves the right to make changes at any time...

Reviews: