Page 26
Notice: Bridge plate and roll stop automatically
function during manual operations.
B
Hand Pump Handle
Release Valve
maximum
3 Nm
minimum
2 Nm
seats
(stops)
OP
EN
C
LO
S
E
AI/B.P. Valve
1-30-92
OP
EN
C
LO
S
E
approximate
1.5 mm intervals
Valve Tightening
Specification:
Once valve seats
(stops), tighten 2
to 3 Nm as shown.
Notice: Close backup
pump release valve
securely before operating
electric pump.
A
Manual Operating Instructions
36514
C
Open
(Down)
Close
(Up/Stop)
D
Release Valve