Page 33
Maintenance and Lubrication Schedule
1500
Cycles
Inspect outer fold arm pins (2), axles (2)
and bearings (8) for wear or damage
and positive securement
Remove pump module cover and
inspect:
• Hydraulic hoses, fittings and
connections for wear or leaks
• Harness cables, wires, terminals
and connections for securement or
damage
• Relays, fuses, power switch and
lights for securement or damage
Replace damaged parts and resecure
as needed. Apply Light Oil.
Resecure, replace or correct as needed.
4500
Cycles
Resecure, replace or correct as needed
Use BraunAbility 32840-QT hydraulic
fluid (Exxon
®
Univis HVI 26). Do not
mix with Dextron III or other hydraulic
fluids. Check fluid level with platform
lowered fully. Fill to maximum fluid
level indicated on reservoir (specified
on decal). Do not overfill. If fluid level
decal is not present - measure 35mm
(1-3/8") from the fill port to locate fluid
level.
Tighten, repair or replace if needed.
Tighten, repair or replace if needed.
Replace if needed.
Tighten or replace if needed.
Replace damaged parts and resecure
as needed. Apply Light Grease during
reassembly procedures.
Replace if needed.
Tighten, replace or correct as
needed
Inspect cotter pins on platform pivot pin
(2)
Hydraulic Fluid (Pump) - Check level.
Notice: Fluid should be changed if
there is visible contamination. Inspect
the hydraulic system (cylinder, hoses,
fittings, seals, etc.) for leaks if fluid level
is low.
Inspect cylinders, fittings and hydraulic
connections for wear, damage or
leaks
Inspect roll stop cylinder hose assembly
(hose, fasteners, connections, etc.) for
wear, damage or leakage
Inspect parallel arms, bearings and
pivot pins for visible wear or damage
Inspect parallel arm pivot pin mounting
bolts (8)
Inspect platform pivot pins, bearings
and vertical arms for wear, damage and
positive securement
Inspect inner/outer fold arms, saddle,
saddle support and associated pivot
pins and bearings for visible wear or
damage
Inspect gas springs (cylinders) for
wear or damage, proper operation, and
positive securement