18 Operating Instructions IQ-ONE / IQ-ONE+
Bräuniger GmbH
A recording interval of 1 second is displayed first. After
further pressure on the Up key 5, and then 15 seconds are
displayed.
In Set-Mode MEMO when flight recording is activate, the instrument starts recording the
flight as soon as it is switched on. (The flight recording interval has to be set to 1s, 5s or
15s). The number of this recorded flight is zero (0).
To record the flight as valid, in the logbook and on a barogram, flight acceptance must be
present. A flight will be accepted when a height difference of more than plus or minus
30m has been recognized and the recorded flying time is more than 2 minutes.
A new flight is started when leaving Set or Option-Mode and no flight acceptance for the
previous flight has been recognized.
When a flight acceptance is present, Set or Option-Mode MEMO, and Set-Mode or
Option-Mode ALT1/2 cannot be entered. This is to prevent changes of height after a
flight has been accepted.
The parameters that can be recorded are
set in Option-Mode MEMO.
Barograph storage capacity.
When the display is completely black, the
memory is full. In future, the oldest flights
will be overwritten.
Time available in flight recorder with the
chosen recording interval; available storage
capacity.
Time interval chosen