1.14.
Calibrate Temperature
The Soldering Iron’s temperature should be recalibrated after replacing
the iron or heating element or nozzle every time. The unit adopts digital
calibration mode and the revision value is input by pressing button to
make the adjustment simply and quickly.
Method of recalibrating temperature: Use the thermometer to calibrate,
and it is precise comparatively.
Calibrate by using thermometer
1.
Set the unit’s temperature to a certain value.
2.
When the temperature stabilizes, measure the tip’s temperature with
thermometer and write down the reading.
3.
Press
“
*
”
button not loose and press the “
▲
”and“
▼
” button
simultaneously, the unit enters into calibrating temperature mode.
4.
At the moment, the 100’s digit of LED display temperature is flashing.
Press the
“▲
”and“
▼
” button to select the value and press
“
*
”
button
to select the digit. Input the reading of thermometer, and inputting
method is the same as
Set temperature normally
. Press“
*
”button
after inputting. Here, the whole calibration operation has been
finished.
5.
If the temperature still has deflection, you can repeat calibration in
accordance with above steps.
* We recommend using the 191/192 thermometer for measuring the tip
temperature.
* If the unit is locked by password, it will not be able to calibrate the
nozzle temperature and you must input the right password.