Operation Instructions
12
Water Supply
1.) Make sure the water supply is clean. Debris can cause excess pump wear and reduce performance.
2.)
An insufficient water supply will damage your pump. Make sure the water supply is steady and is 20%
over the rated flow of your pump. Use a stopwatch to time how long it takes to fill a 5-gallon bucket with
your garden hose. The bucket must fill faster than the times listed in the table below.
Model
Time to fill a 5 gal. bucket
BR1517ECO
150 seconds
3.) The water supply garden hose must have an inside diameter of at least 5/8”. If the hose is more than 100 ft.
long, the diameter must be at least 3/4”.
4.) Never use a reservoir tank as a water source. Drawing water out of a tank may cause pump cavitation and
damage to your pump. This pressure washer is designed for a pressurized water source such as a city water
faucet. However, the water source pressure must not exceed 115 psi (8 bar).
Always use a flexible rubber hose for your water supply. Do not use rigid piping.
SHUT-DOWN INSTRUCTIONS
1. Turn motor OFF.
2. Unplug the power cord.
3. Turn water supply OFF.
4. Squeeze trigger to
relieve system pressure.
5. Remove garden hose.
6. Remove pressure hose.
START-UP INSTRUCTIONS
1. Attach garden hose.
2. Attach pressure hose.
3. Attach gun and lance.
4. Turn water supply ON.
5. Squeeze trigger to
purge air from pump.
6. Insert nozzle.
7. Plug in power cord
8. Reset the GFCI button on the cord.
Skin puncture hazard.
High pressure fluid can inject under skin resulting in serious injury including
amputation. Do not direct spray at people or animals.
-If skin injection happens, seek IMMEDIATE surgical treatment.
-Do not check for leaks with hand. Instead, use a piece of cardboard to check for
leaks.
-Do not use unit if exterior hose damage is evident. Make sure all fittings are tight
before starting. Relieve system pressure before servicing.
-Know how to stop engine and bleed pressures quickly. Be thoroughly familiar with
the controls.
-Make sure accessories meet the unit's temperature and pressure limits.
-Stop engine and bleed pressures before leaving unit unattended.
WARNING
Summary of Contents for BR1517ECO
Page 2: ...Hazard Signal Word Definitions 2 ...
Page 11: ...Pump Component Identification 11 Note Discard Shipping Plug and O ring BR1517ECO ...
Page 21: ...Parts Explosion BR1517ECO Rev A 1 21 ...
Page 23: ...Pump Exploded View Rev A 1 23 Part 790693 Comet AXD 1617E GH ...
Page 26: ...26 This page was intentionally left blank ...
Page 28: ...28 BRAVE 20195 S Diamond Lake Rd STE 100 Rogers MN 55374 ...