Troubleshooting
19
Problem
Solution
Motor will not start
SOLUTION: A,B
Low/Surging pressure or no water flow
SOLUTION: C,D,E,F,G,H
No chemical injection
SOLUTION: I,J,K,L
Cause
Solution
A-
Tripped GFCI cord
Reset GFCI cord
B-
Tripped motor relay
Reset motor
C-
Insufficient water supply
See water supply section of this manual
D-
Plugged pump inlet filter
See maintenance section of this manual
E-
Wrong nozzle
Make sure high pressure nozzle is being used
F-
Plugged nozzle
Remove nozzle, check for blockage
G-
Worn nozzle
Replace nozzle
H-
Leak in pressure hose
Replace pressure hose
I-
Wrong nozzle
Make sure chemical nozzle is being used
J-
Back pressure from extra-long discharge hose
Try shorter hose
K-
Leak in chemical siphon hose
Replace hose – use hose clamps if necessary
L-
Chemical strainer not submerged
Make sure strainer is completely submerged
The manufacturer reserves the right to make improvements in design and/or
changes in specifications at any time without incurring any obligation to install
them on units previously sold.
Any Questions, Comments, Problems or Parts Orders
Call BRAVE Product Support 1-800-350-8739
Summary of Contents for BR1517ECO
Page 2: ...Hazard Signal Word Definitions 2 ...
Page 11: ...Pump Component Identification 11 Note Discard Shipping Plug and O ring BR1517ECO ...
Page 21: ...Parts Explosion BR1517ECO Rev A 1 21 ...
Page 23: ...Pump Exploded View Rev A 1 23 Part 790693 Comet AXD 1617E GH ...
Page 26: ...26 This page was intentionally left blank ...
Page 28: ...28 BRAVE 20195 S Diamond Lake Rd STE 100 Rogers MN 55374 ...