Start-up Procedure
WARNING
To prevent a fire hazard or possible explosion which could result
in serious injury, do not smoke or have open flames when
refueling the engine. Do not spill fuel. If fuel should spill, quickly
wipe up the spill and move the log splitter away from the area before continuing.
Make sure gasoline-soaked rags are disposed of properly.
4
. Fill the engine’s fuel tank with fresh, clean, lead-free automotive gasoline. Fill to
approximately 1-1/2” below top of neck to allow for expansion. The supplied engine is
a 4-cycle engine, so do not mix oil with the fuel.
5
. Now start the engine according to the engine manufacturer’s instruction.
(Refer to the engine manual.) Allow the engine to warm up.
WARNING
Keep all body parts away from the slide area when cycling the cylinder.
6
. Push the valve control handle, with one hand, to the forward (extend) position
(towards the front of the cylinder). When the push plate is fully extended, push the
valve control handle backwards to the retract position and retract the cylinder piston.
The cylinder valve will automatically stop the cylinder from retracting when it reaches
the end of its stroke. Fully cycle the cylinder 2 to 3 times, finishing with cylinder in the
retracted position.
NOTE:
Extending and retracting the cylinder piston draws the hydraulic fluid through the
system and expels any trapped air in the system.
7
. Turn off the engine.
8
. Make sure the log splitter is flat and level. Remove the fill cap and oil level screw and
slowly add approximately 3 quarts (2.8 liters) of additional oil just until it runs from the
oil level hole. Allow enough time for excess oil to drain from oil level hole. Re-install
fill cap and oil level screw making sure O-rings are in place.
9
. Check all fittings and hoses for leaks and tighten as needed. Your EZ Split 15 log
splitter is now ready to use.
Summary of Contents for PCLS1513
Page 34: ...Brave 32 800 350 8739 Decals 2 1 3 ...
Page 35: ...Decals 800 350 8739 33 Brave 4 CONTROL VALVE Reverse Neutral Forwar d 5 ...
Page 36: ...Decals Brave 34 800 350 8739 CONTROL VALVE Reverse Neutral Forward 6 7 8 9 10 ...
Page 44: ......
Page 45: ...Notes 800 350 8739 43 Brave ...
Page 46: ...Brave 800 350 8739 44 Notes ...
Page 47: ......