Operation
8
.
DO NOT
load another log or remove split
pieces until the pusher plate has
completely stopped and the control handle
automatically returns to the neutral
position.
Splitting Large Logs
When splitting a large log, or one in which the
wood is extremely tough or stringy (such as
elm), the first pass through the splitter may
not split the log into two sections. If this
happens, turn the log and split off small
sections. Repeat this process as necessary
to split the entire log.
Inspection and Maintenance
General Maintenance Check (before operating)
The hydraulic system (hoses, cylinder, and pump) should be carefully inspected before
each use. Also, inspect the mechanical parts at the same time. Make sure all clamps,
nuts, bolts, fittings, etc. are properly installed and tightened.
Oil Level Check
CAUTION
Do not remove the oil level screw or fill cap from the hydraulic tank or
reservoir while the log splitter is running. Hot oil, under pressure, could
be expelled resulting in serious injury. Turn off the engine and allow the
log splitter to cool for a few minutes to relieve pressure before checking the
hydraulic oil level.
It is critical that the proper hydraulic oil level is maintained and the oil level should be
checked periodically. Be sure the EZ Split 15 is on a flat, level surface before checking
the oil level.
1
. Place a clean container under oil level hole to catch any overflow of oil. Do not allow
excess oil to spill onto the ground.
Summary of Contents for PCLS1513
Page 34: ...Brave 32 800 350 8739 Decals 2 1 3 ...
Page 35: ...Decals 800 350 8739 33 Brave 4 CONTROL VALVE Reverse Neutral Forwar d 5 ...
Page 36: ...Decals Brave 34 800 350 8739 CONTROL VALVE Reverse Neutral Forward 6 7 8 9 10 ...
Page 44: ......
Page 45: ...Notes 800 350 8739 43 Brave ...
Page 46: ...Brave 800 350 8739 44 Notes ...
Page 47: ......