05
-
2015 Rev.1
2.
20
Parte 2 Prescrizioni di Sicurezze
2.28
The additional load of the Platform MUST NOT:
-
Exceed the working load limit (See Part 3, Specifications)
-
Stick out from the basket, but must be well balanced.
2.29
It is strictly forbidden to use the Platform as a crane .
2.30
The operator must monthly check the state of tightening of
ALL the screws and if necessary replace them (Section
9.8 Maintenance)
.
2.31
Attenzione Pericolo di Shock elettrico
.
E
’
vietato l
’
uso della Piattaforma vicino alla linee elettriche di
tensione non protette.
La Piattaforma e la recinzione non sono isolate elettri-
camente
.
Do not operate the platform near power lines
Keep a distance of at least 3 m (10 ft) between the parties
of the machine and the occupants, with their relative tools
and equipments, and a power line or equipment provided
with a electric charge up to 50.000 volts.
It is possible to reduce the minimum safe operating dis-
tance in presence of insulating barriers installed to pre-
vent contacts and if these barriers are set to the voltage of
the power line to be protected.
The barriers should not be a part of the machine or be
connected to it.
The minimum safe operating distance should be reduced
within the provided operating dimensions of the insulating
barrier.
This distance should be determined by a qualified person
in accordance with the company, local and government
regulations regarding the conduct of the work near equip-
ments under voltage.
04
-
2020 Rev.01
P
ART 2 SAFETY PRESCRIPTIONS
VOLTAGE RANGE
(FROM PHASE TO PHASE)
MINIMUM OPERATIONAL
SAFETY DISTANCES m (ft)
From 0 to 50 kV
3 (10)
From over 50 kV to 200 kV
5 (15)
From over 200 kV to 350 kV
6 (20)
From over 350 kV to 500 kV
8 (25)
From over 500 kV to 750 kV
11 (35)
From over 750 kV to 1000 kV
14 (45)
NOTE: These minimum operational safety distances are to be applied
except in cases in which company, local or governmental regulations are
more stringent.