CORRECTING MALFUNCTIONS
In case of malfunctions first consult the malfunctions tables. If the problem cannot be solved, consult
your Bravilor Bonamat dealer, your service mechanic or one of the service desks.
8.1
Malfunctioning analysis general
LIST OF MALFUNCTIONS
Symptom:
Possible cause:
Actions:
1. The machine does not work
and there is nothing on the
di
l
The plug is not connected to the
power socket.
Connect the plug to the power
socket.
g
display.
External fuse has blown.
Reset or replace the external
fuse.
Group is overloaded.
Connect the machine to another
group.
2. Sometimes water comes out
of the outlet without reason.
Temperature has been set so
high that the water starts
boiling.
Set the temperature at a lower
value, see §6.2.5.
3. The descaling symbol
appears on the display.
Set number of liters of the
descaling signal has been
reached.
Descale the machine, see §7.1.
4. A flashing cup and saucer
appear on the display.
The door is open.
Close the door (with the key).
8.2
Malfunction analysis brewer
LIST OF MALFUNCTIONS
Symptom:
Possible cause:
Actions:
1. Brewer does not move
smoothly.
Clamping force of the brewer
room is too strong.
Call in service.
2. Coffee residue too wet.
Clamping force of the brewer
room is too weak.
Call in service.
Brewer filter is clogged.
Clean the filter, see §5.2.3.1.
Brewer stop S2 too low.
Increase brewer stop S2,
see §6.2.4.1.
Leak between the brewer piston
and the cylinder.
Call in service.
3. Coffee grounds in coffee.
Filter paper missing.
Provide filter paper, see §5.1.4.
Paper does not run straight.
Correct the paper routing,
see §5.1.4.
Packing leaks.
Call in service.
Clamping force of the brewer
room is too weak.
Call in service.