GB
E
Copyright Bravilor Bonamat B.V.
3
1.5
Maintenance
1.5.1
Daily
1. Remove the complete drip tray.
2. Wash all components in hot water with a
normal washing
−
up liquid.
1.5.2
Once a week
1. Remove the drip
−
tray.
2. Dissolve 1 bag of
Cleaner
in
3
l of water
(min. 80
_
C).
3. Immerse the parts to be cleaned in this
solution.
4. Leave to steep thoroughly (max. 30 min.).
5. Thoroughly rinse the parts with hot water.
6. Wipe the outside of the machine with a damp
cloth. When cleaning,
never
use an abrasive
or corrosive cleaning product.
7. Dry the machine with a soft cloth.
8. Replace the drip tray in front of the machine.
1.5.3
Descaling
1.5.3.1 Descaling indicator
During use, a scaling process will take place
inside the machine. The coffee, hot
−
water, and
steam modules are provided with a descaling
warning system that indicates when the
machine must be descaled.
1.5.3.2 Setting descaling signal
Only for Modules 3, 4, 7 and 8.
The number of litres of water flowing through the
module before the descaling warning system is
activated, can be adjusted.
D
Bear in mind the hardness of the water (see
table 3 ).
Position
Signal after
number of
Water hardness
number of
liters
5
DH
5
TH
Description
OFF
No signal
−
−
−
1
±
250
liter
18
−
3
0
32
−
5
5
hard
2
±
500
liter
12
−
1
8
22
−
3
2
rather hard
3
±
1000
liter
8
−
1
2
15
−
2
2
average
4
±
1500
liter
4
−
8
7
−
1
5
soft
5
±
2000
liter
0
−
4
0
−
7
very soft
4,0
°
DH = 0,714 mmol/
liter
5,6
°
DH = 1,000 mmol/
liter
8,0
°
DH = 1,429 mmol/
liter
12,0
°
DH = 2,143 mmol/
liter
18,0
°
DH = 3,214 mmol/
liter
30,0
°
DH = 5,357 mmol/
liter
10,0
°
TH = 1,000 mmol/
liter
Table 3 Water hardness settings
TIP
−
Ask your local water company about the
hardness of the water they supply.
Bravilor Bonamat BV