Turn on power supply and check the static current whose normal value should be 10A~
12A.
When the PA works with full power, the current should be 33A~35A.
4
、
RF performance test procedure:
1) Spectrum emission
Test flow chart:
Purpose:
Check the quality of amplified signal.
Test setup list
Signal generator: Agilent IFR3413 or the same level instrumentation.
Power meter: Agilent E4418B or the same level instrumentation.
Spectrum analyzer: R&S FSEA or the same level instrumentation.
Power supply: 30V/50A
Attenuator: 30dB 500W 1PCS, 20dB 5W 2PCS,
Coupler: 60dB frequency range: 1930MHz~1990MHz
Signal
Generator
LPA1900-120
-SC01
10dB coupler
30dB
Attenuator
20dB
Attenuator
20dB
Attenuator
Power
Supply
Spectrum
Analyzer
Power
Meter
Figure 1
Cable1
Cable2
Cable3