Keep carefully these instructions for use as this booklet provides necessary information for the good
use of the equipment.
Before connecting the device to the mains, check the values on the device (volts and Hz) and your
distribution network.
The warranty does not cover faulty connections.
Fragile medical device, to be manipulated with care.
Keep this medical device out of the reach of children or animals (potential risks with the tubes and
detachable part of the accessory).
Connect the device to an easily accessible plug, to allow a rapid disconnection from the mains.
The device has to be installed and put into service according to the information supplied with the
attached documents.
I
I
M
M
P
P
O
O
R
R
T
T
A
A
N
N
T
T
R
R
E
E
M
M
A
A
R
R
K
K
S
S
:
:
Make sure no milk penetrates into the interface bottle or into the pump.
Do not use Expression Kits KOLOR
®
with a free control breastpump (ref. KV, KL, KLR, KBOX, KBOXR) and
do not connect them to the central vacuum hospital system.
The European version of the KOLOR
®
breast shield (i.e. with European thread)
can only be used
with a corresponding baby bottle (same thread).
Should the pump not work properly, please check that:
The Kolor
®
breast shield is well screwed on the baby bottle(s) (screw completely),
The cap of interface bottle is correctly fitted,
The tubes are well connected and not pinched.
This medical device is directly connected to the electric power supply, do not use it in bath or under
the shower, do not immerse.
Keep this medical device away from any high heat source.
Store properly the electric cord and the tubes after each use.
Kitett devices are designed to operate at altitudes less than or equal to 3 000 meters.
No special knowledge or training is required to use Kitett devices.
An animal can eat the electric cord. Thoroughly check the state of the equipment before use.
The mains plug is the disconnecting device and must always be accessible.
P
P
A
A
R
R
T
T
I
I
C
C
U
U
L
L
A
A
R
R
W
W
A
A
R
R
N
N
I
I
N
N
G
G
S
S
:
:
Do not open the device when connected to the main (electrical shock hazard).
Should the circuits have to be rinsed, entrust the operation to a maintenance professional (risk of bad
handling).
Watch for the good making of the sessions due to hazard of exceeding the regulation parameters and
modifying the applied depression.
This device is to be used either in health care establishment or at home.
Do not use the device outdoors, near a heat source or near a waterhole (bathtub, sink…)
.
After use, disconnect the device from the mains.
Make sure the device is not exposed to direct sunlight or excessive heat.
Do not touch the device box for more than 1 second during use.
The tube connecting the collecting bottle to the device can reach the temperature of 43.5 °C. The user
should not touch the tube for more than 10 minutes during device use.
The patient is an intended operator. He can use all functions of the device safely.
If necessary, contact the manufacturer if you need help to set up, use or maintain the medical device,
and to report any unexpected operation or event.