background image

2 Ussc

OPTIONAL ACCESSORIES

DESCRIPTION

PART #

B36 Blower Assembly - 100 CFM

69354

Combustion Air Adapter

892021

CONGRATULATIONS!

You’ve purchased a heater from North America’s oldest manufacturer of wood burning products.

By heating with wood you’re helping to CONSERVE ENERGY!

Wood is our only Renewable Energy Resource. Please do your part to preserve our wood supply. Plant at least one 

tree each year. Future generations will thank you.

The instructions pertaining to the installation of your wood stove comply with UL-1482-2011 and ULC-S627-2000 standards.

CAUTIONS:

•  HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. 

CONTACT MAY CAUSE SKIN BURNS.

•  DO NOT USE CHEMICALS OR FLUIDS TO IGNITE THE FIRE.
•  DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED.
•  DO NOT BURN GARBAGE, FLAMMABLE FLUID SUCH AS GASOLINE, NAPHTHA OR 

MOTOR OIL.

•  DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
•  ALWAYS CLOSE THE DOOR AFTER THE IGNITION.

Combustible :

Model

Wood

Colors :

Metallic Black

Flue Pipe Diameter :

6” (15.3cm)

Flue Pipe Type: (Standard Single Wall or Double Wall):

Black or Blued Steel 2100°F (650°C)

Minimum Chimney Hieght :

12’ (3.7m)

Maximum Log Length :

21” (53.4cm)

Dimensions
Overall 

:

Depth x Width x Height :

SW2100

23” x 27 

1/4

”  x 34 

1/8” 

(58cm x 69cm x 87cmm)

SW3100

27 

1/2

” x 27 

1/4

  

x 40

” 

(70cm x 69cm x 102cm)

Combustion Chamber :

Width x Depth :

SW2100

22 

3/4”

 x 12

” 

(58cm x 30.5cm)

SW3100

22 

3/4”

 x 16 

1/2” 

(58cm x 42cm)

Volume :

Cubic Feet:

SW2100

1.86 ft³ (.0527m³)

SW3100

2.69 ft³ (.0761m³)

Door Opening : 

Width x Height:

16” x 8” (41cm x 20cm)

Pyroceramic Door, Glass : (Viewing) 

Width x Height:

14 

7/16

” x 9 

1/8” 

(37cm x 23cm x 5MM THK)

Weight (lbs):

SW2100

300 lbs (136kg)

SW3100

350 lbs (159kg)

Summary of Contents for SW2100

Page 1: ...th Improper Installation Could Void Your Warranty SAFETY TESTED TO UL 1482 2011 and ULC S627 2000 US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOODSTOVE WASHINGTON STATE APPROVED MOBILE HOME...

Page 2: ...STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED DO NOT BURN GARBAGE FLAMMABLE FLUID SUCH AS GASOLINE NAPHTHA OR MOTOR OIL DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM ALWAYS CLOSE THE DOOR...

Page 3: ..._____ Reason for Purchase qAlternative Heat qMain Heat Source qDecoration qCost qOther_________________________ What was the determining factor for purchasing your new appliance _______ I have read th...

Page 4: ...4 Ussc CUT HERE CUT HERE Fold Here Fold Here United States Stove Company P O Box 151 South Pittsburg TN 37380 Fold Here Place Stamp Here...

Page 5: ...or as specified in this manual All chimney and chimney connector components required for your particular chimney installation For mobile homes see page 13 Assembly Flue Collar Assembly 1 Mount the flu...

Page 6: ...f tight construction or not a manufactured mobile home you can just simply remove the 4 round knockout in the rear of the pedestal Combustion Air thru Unit Base installation First decide the location...

Page 7: ...H AIR INTO THE ROOM OR SPACE HEATED SHALL BE PROVIDED WHEN REQUIRED POSITIONING THE STOVE It is very important to position the wood stove as close as possible to the chimney and in an area that will f...

Page 8: ...ith a required thickness T in inches R 1 k x T C factor is given R 1 C Example If the floor protector is 4 brick with a C factor of 1 25 over 1 8 mineral board with a k factor of 0 29 the total R valu...

Page 9: ...st not pass through an attic or roof space closet or similar concealed space a floor or a ceiling For Canadian installations where passage through a wall or partition of combustible construction is de...

Page 10: ...the section toward the chimney Any installation with a horizontal run of chimney pipe must conform to NFPA 211 You may contact NFPA National Fire Protection Association and request the latest edition...

Page 11: ...the draft effect your stove s performance is directly dependent on an adequate draft from your chimney The following recommendations may be useful for the installation of your chimney 1 Do not connec...

Page 12: ...same manufacturer and install the ceiling support package or wall pass through and T section package firestops where needed insulation shield roof flashing chimney cap etc Maintain proper clearance t...

Page 13: ...s sociation NFPA by having it inspected by a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed...

Page 14: ...chimney connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm sep aration area contain...

Page 15: ...rafts occur whether or not there is combustion present 3 Opening a window slightly on a calm windless day alleviates any of the above symptoms 4 The house is equipped with a well sealed vapor barrier...

Page 16: ...conditions it may rot instead of drying This point cannot be over stressed the vast majority of the problems related to the operation of a wood stove is caused by the fact that the wood used was too d...

Page 17: ...the following burn procedures HEATING Controlled combustion is the most efficient technique for wood heating because it enables you to select the type of combustion you want for each given situation...

Page 18: ...nse in the relatively cool chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this creosote makes an extremely hot fire The chimney connector...

Page 19: ...riking or slamming shut Do not use the stove if the glass is broken If the glass on your stove breaks replace only with the glass supplied from your heater dealer Never substitute other materials for...

Page 20: ...20 Ussc REPAIR PARTS SW2100 1 20 21 24 25 23 28 33 34 30 29 31 32 37 17 27 3 2 5 4 8 6 9 7 10 26 22 38 36 35 39 19 18 11 12 13 14 15 16...

Page 21: ...20 Plate Hearth 1 20 40292A 6 Flue Collar 1 21 88042 1 4 Rope Gasket 1 22 69665 Assembly Pedestal 1 23 83431 Weld Tab 3 24 83432 5 16 18 x 1 1 2 Bolt 3 25 83045 Washer 5 16 ID x 3 4 OD x 1 16 THK 3 26...

Page 22: ...22 Ussc REPAIR PARTS SW3100 20 18 19 22 21 31 32 26 28 27 29 30 25 3 2 4 5 15 34 9 10 11 12 13 14 17 16 33 24 23 7 6 8 1...

Page 23: ...Assembly Pedestal 1 24 892019 Back Pedestal 1 25 892010 R Mounting BRKT Shroud 1 26 892011 L Mounting BRKT Shroud 1 27 892009 Shroud Mount Rear 2 28 69705 Weldment Shroud 1 29 892008 Rear Shroud Panel...

Page 24: ...odel number which is on the nameplate attached to the heater when ordering repair parts always give the following infor mation as shown in this list 1 The part number 2 the part description 3 the mode...