6
INSTALLATION
INSTALLATION
COMBUSTION AIR SUPPLY
For a mobile home installation, the stove must be connected
to an outside source of combustion air. A 2” inside diameter
metallic pipe, either
fl
exible or rigid, may be attached to the inlet
at the stove’s rear (refer to
fi
gure 3). A rodent guard (minimum
1/4” wire mesh) wind hood must be used at the terminus (refer
to
fi
gure 4). All connections must be secured and airtight by
either using the appropriately sized hose clamp and/or UL-181-
AP foil tape.
For mobile home installations only:
2” inside diameter pipe
may be used for the
fi
rst 5 feet of combustion air supply run.
From 5 to 10 feet, use 2 3/4” inside diameter pipe. No combus-
tion air supply may exceed 10 feet.
Sources of Outside Combustion Air
a. In
fi
replaces
Chimney top.
Ash clean out door.
b. For freestanding installations
A hole in
fl
oor near stove rear terminating only a ven-
tilated crawl space.
A hole in the wall behind the stove.
WHEN OUTSIDE AIR IS NOT USED
If outside air is not used, it is important that combustion air is
easily available to the air inlet. A closeable outside air register
can be used in tightly insulated homes.
VENTING
The
Big E is certi
fi
ed for use with listed TYPE L-Vent, 3” or 4”
diameter in size. The stove was tested with Simpson Duravent
brand. CLass “A” chimney is not required. Refer to the instruc-
tions provided by the vent manufacturer, especially when pass-
ing through a wall, ceiling or roof.
This is a pressurized exhaust system. All vent connector joints
must be sealed with 500
o
F (260
o
C) RTV silicone sealant to
ensure consistent performance and avoid smoke spillage. All
horizontal connector joints must be sealed with UL-181-AP foil
tape. All vertical vent connector joints are required to be se-
cured with a minimum of 3 screws.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERV-
ING ANOTHER APPLIANCE.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST
VENTING SYSTEM OF THIS UNIT.
INSTALL VENT AT CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER.
The chimney connector shall not pass through an attic or
roof space, closet or similar concealed space, or a
fl
oor,
or ceiling. Where passage though a wall, or partition of
combustible construction is desired, the installation shall
conform to CAN/CSA-B365, Installation Code for Solid-Fu-
el-Burning Appliances and Equipment
FIGURE 3
FIGURE 4
25 34
“
32 58
“
65
8
“
8 78
“
7 5
16
“
2 7
16
“
TRIM
COLLAR
VENTILATED
CRAWL SPACE
RODENT
GUARD