INSTALLATION
24
•
All control cables outside the enclosure must be
shielded and have a cross sectional area
between 0.22 mm
2
and 1 mm
2
(23 and 18
AWG). The shielding must be connected to
earth at just one end. In case of doubt, consult
your Bredel representative.
5.4
Lifting and moving the pump
The pump supports each have a lifting eye (A) for lifting
and moving the hose pump.
The complete hose pump, i.e. pumphead, gearbox and
electric motor, must be lifted using the lifting eyes and
suitably rated straps or slings (A). For the weights, refer
to §
.
The pumphead can be lifted by using the lifting lug (B).
5.5
Placing the pump
Position the pump on a horizontal surface. Use suitable
anchor bolts to attach the pump to the floor surface.
A
A
A
B
WARNING
If the pump is to be lifted ensure that all
standard lifting practices are adhered to
and carried out by qualified personnel only.