RSSI Measurement and Maximum Data Rate Configuration
BreezeACCESS 2.4 Series
21
SU-A/E Subscriber Units Installation Manual
6. RSSI MEASUREMENT AND MAXIMUM DATA
RATE CONFIGURATION
6.1 Performing the RSSI Measurement
The Continuous Link Quality Display test allows a continuously updated display
of the average Received Signal Strength Indication. As the test measures only the
desired signal of properly received frames, it is a good indication to the quality
of the received signal.
Note:
As the RSSI bar indicator is not accurate, it is recommended always to
perform the Continuous Link Quality Display test after the antenna was
optimally aligned.
1. Start the Monitor program as described in Section 3.1.
2. From
the
Main Menu Type 4 to access the Site Survey menu.
3. Type 4 to activate the Continuous Link Quality Display selection screen.
4. On the screen you will get a continuously updated display of RSSI
measurements. To stop the test, press the Esc key.