Aligning the Antenna
SU-I/ID Installation Manual
16
BreezeACCESS MMDS Series
4.2 Aligning the Antenna Using the Site Survey Menu
1. Start the Monitor program as described in Section 3.1.
2. From
the
main menu, type 4 to access the Site Survey menu. Type 4 to start
the Continuous RSSI Display. Each line in the display includes the number
of frames that were received since the last measurement (total Rx) and the
average RSSI for these frames.
3. Rotate the antenna left and/or right until you reach the point of maximum
RSSI reading. Make sure that at all times, the front of the antenna faces the
general direction of the Base Station.
4. For proper operation, the RSSI reading should be at least 52 units. When the
maximum reading is less than 52 units, try to improve it by placing the
antenna at a higher point or in a different location. For best performance it is
recommended that the RSSI be higher than 76.
5. Press
the
Esc
key to stop the test.
6. Tighten the U-bolts (or metal band) over the antenna to secure it to the pole.