MAINTENANCE
Regularly check the battery for damage.
TECHNNICAL DATA:
Operating voltage
230 V~ 50 Hz
Switch voltage
230 V~ 4.35 A
Switch outlet switching capacity
max. 1000 W
Wireless signal range
max. 25 m
Frequency band
433.05 MHz – 434.79 MHz
Operating frequency
433.92 MHz
Max. transmitting power
≤
5 dBm
Ambient temperature
0 ° to 35 °C
Storage temperature
- 40 ° to 70 °C
Battery
12 Volt, Type A 23
EC-compliant
FAULT RECTIFICATION
18
RCS 1000 N Comfort
Fault
Cause
Repair
Function lamp (4) does
not illuminate when a
button is pressed.
Battery incor-
rectly inserted.
Insert the bat-
tery correctly.
Battery does not
have contact.
Press the battery
against the con-
tact terminals.
Battery is empty. Insert a new
battery.
Function lamp (6)
does not illuminate
Switch outlet not
properly
connected.
Plug the switch
outlet firmly
into the outlet.
Function lamp (6) does
not illuminate, device
does not work.
Device not swit-
ched on.
Switch on the
device.
079615 BA_Funkschaltset RCS 1000 N.qxp 12.06.17 15:16 Seite 18
Summary of Contents for RCS 1000 N Comfort
Page 65: ...220 240 V 50 Hz 65 079615 BA_Funkschaltset RCS 1000 N qxp 12 06 17 15 16 Seite 65...
Page 66: ...2012 19 66 RCS 1000 N Comfort 079615 BA_Funkschaltset RCS 1000 N qxp 12 06 17 15 16 Seite 66...
Page 74: ...220 240 50 74 079615 BA_Funkschaltset RCS 1000 N qxp 12 06 17 15 16 Seite 74...
Page 75: ...75 RCS 1000 N Comfort 079615 BA_Funkschaltset RCS 1000 N qxp 12 06 17 15 16 Seite 75...
Page 84: ...2 84 RCS 1000 N Comfort 079615 BA_Funkschaltset RCS 1000 N qxp 12 06 17 15 16 Seite 84...
Page 113: ...079615 BA_Funkschaltset RCS 1000 N qxp 12 06 17 15 17 Seite 113...
Page 114: ...079615 BA_Funkschaltset RCS 1000 N qxp 12 06 17 15 17 Seite 114...
Page 115: ...079615 BA_Funkschaltset RCS 1000 N qxp 12 06 17 15 17 Seite 115...