Intended use

The devices which constitute this RF remote control switch set are intended only 

for personal use in closed dry rooms. They are not suitable for commercial use.
The RF remote control switch set is used for switching lamps and electrical 
appliances on and off. The devices may only be operated individually. 
Do not plug multiple socket switches into each other. Any other use is considered 

non-intended use. The manufacturer assumes no liability for damage caused 
by non-intended use.

Technical data

Operating voltage 

230 VAC 50 Hz

Switching voltage  

230 VAC 4,35 A

Socket switch switching power  

max. 1000 W

Radio signal range  

max. 25 m

Operating frequency  

433.92 MHz

Ambient temperature  

0°C to 35°C

Storage temperature  

-40°C to 70°C

CE-compliant

Adjust the DIP switches using a suitable object, 

for instance a small screwdriver, by pushing them down or up.

    

WASTE DISPOSAL

    

Dispose of electrical devices in an environmentally

   

  friendly manner!

   

  Electrical devices do not belong in the household rubbish. In accordance 

with European Directive 2002/96/EC on waste electrical and electronic equipment 
old power tools must be collected separately and sent to a proper recycling facility.

You can found out more about the options for disposing of used devices from your 
local government or municipal authorities.

Basic safety instructions

  Children are not aware of the dangers that may arise from improper

  handling of electrical devices. Never allow children to use electrical devices 
  without supervision.

  Risk of suffocation! Do not leave the packaging material lying around. 

  Children could swallow the small parts and choke on them.

  Plug the socket switches into conventional 220-240VAC/50Hz two-pin earthed 

  sockets only.

  Do not connect the socket switches to extension cables.

  Only connect consumers which do not exceed the performance limits of the 

  socket switches.

  Do not connect consumers (for example irons) which could cause fi re or other 

  damage if they are accidentally switched on.

  Do not connect consumers (for example refrigerators) which require condenser 

 motors.

  Do not cover the socket switches. Heat builds up under the cover. 

  This poses a fi re hazard.

  Regularly check the devices for damage. Do not replace damaged parts. 

  Contact the manufacturer or dispose of the devices in an environmentally 

  friendly manner.

  Do not touch the devices with wet hands.

  To de-energise the socket switches disconnect them from the mains supply.

Operating manual

Read this operating manual through thoroughly before using the device. 

Keep the operating manual in a safe place. Should you pass on this device to 
another party be sure to include the operating manual.

Synchronising the system code

Before using the devices for the fi rst time the system code must be synchronised to 
enable all socket switches to react to the radio signal of the remote control.

Moreover, each socket switch must be assigned a frequency of a key pair on the 
remote control to enable it to be operated individually.

Setting a system code on the socket switch

1.  Undo the screw (9) of the cover (6) using a PH0 Phillips screwdriver.
2.  Slightly raise the cover (6) above the screw hole (5) and push out.
3.  Set the same system code as for the App using DIP switches 1 to 5 (7).

Assigning a socket switch to a control key

1.  Set a control key on the remote control using DIP switches A to E (7):

Control key

DIP switch

A

B

C

D

E

A

ON

OFF

OFF

OFF

OFF

B

OFF

ON

OFF

OFF

OFF

C

OFF

OFF

ON

OFF

OFF

D

OFF

OFF

OFF

ON

OFF

2.  Push the cover in (6) and close.

3.  Insert the screw (9) through the screw hole (5) into the thread (8) and tighten.

Connecting the devices

The radio signal has a range of up to 25 m (dependent on structural conditions).

DIP switch E is not occupied.

The range can be affected by structural conditions (for example 

reinforced concrete), electrical conditions (for example electrical lines) 
or electromagnetic conditions (for example telephones). If necessary 
remove the source of interference or maintain a suff cient distance 

to the source of interference.

Switching on a socket switch

 1.  Plug the socket switch (1) into a socket.

2.  Plug the consumer into the two-pin earthed socket (2).
3.  Switch the socket switch (1) via app on. 
  The function indicator light (4) illuminates.

Switching off a socket switch

Switch the socket switch (1) via app off. 

The function indicator light (4) goes out.

Reinigung

Caution! Risk of electric shock.

Before cleaning the device disconnect it from the mains supply.
Ensure that no liquid penetrates into the device. Liquid which
enters the device can cause short-circuiting.

Caution! Risk of damage from aggressive cleaning agents.

Never use aggressive or abrasive cleaning agents for cleaning.
Clean the device with a soft damp cloth and a mild cleaning agent. 
Ensure that the device is completely dry before using it again.

Troubleshooting

Fault

Possible cause

Remedy

Function indicator
light (4) does not
light up.

Socket switch has not been
connected correctly.

Push the socket switch 
formly into the socket.

Function indicator
light (4) lights up, 
but consumer does 
not work.

Consumer has not been
switched on.

Switch on the consumer.

Socket switch does

not switch on.

System code of the socket 

switch has not been set
correctly.

Set the system code of 
the App and on the socket 
switch.

Electrical devices are 
causing interference.

Remove possible sources of
interference.

Manufacturer

Hugo Brennenstuhl GmbH & Co. KG 

 

Seestr. 1-3 · 72074 Tübingen · Deutschland
www.brennenstuhl.com

Conformity declaration

The conformity declaration can be found at the following link:

www.brennenstuhl.com/konformitaetserklaerung/ke_1507450.pdf

1  Socket switch 

6  Cover

2  Childproof two-pin earthed socket 

7  DIP switches

3  Two-pin earthed plug 

8  Thread

4  Function indicator light 

9  Screw

5  Screw hole

GB