16
TROUBLESHOOTING
Problem/Symptom
Solution
Strange or no measure-
ment of rain sensor
1. Check drain hole in the rain collector.
Clean it if neccessary.
2. Check the circular level. Realign the
device if neccessary.
Strange or no measure-
ment of Thermo/Hygro
Sensor
1. Check radiation shield. Clean it if
neccessary.
2. Check sensor housing. Clean it if
neccessary
and
---
(no signal
for 15 minutes)
1. Relocate main unit and 5-in-1 sensor
closer to each other.
2. Make sure the main unit is placed
away from other electronic appliances
that may interfere with the wireless
communication (TV‘s, computers,
microwaves).
3. If problem continues reset both, main
unit and 5-in-1 sensor.
and
ER
(no Signal for
1 hour)
SPECIFICATIONS
Main unit
Batteries
3 x AA, 1.5 V
Barometer unit
hPa, inHg, mmHg
Barometer measuring range
540 - 1100 hPa
Temperature unit
°C / °F
Temperature measuring range
-10° - 50° C
Humidity measuring range
20% - 90%
Time display
HH:MM:SS
Time format
12 or 24 hours
Calendar display
TT/MM/JR or MM/TT/JR
5-in-1 sensor
Batteries
3 x AA, 1.5 V
Temperature unit
°C / °F
Temperature measuring range
-40° - 60° C
Humidity measuring range
1% - 99%
Rainfall unit
mm, inch
Rainfall measuring range
0 - 9999 mm (0 - 393.7 inch)
Wind speed unit
mph, m/s, km/h, knot
Wind speed measuring range
0 - 112 mph, 0 - 50 m/s, 0 - 180
km/h, 0 - 97 knots
Wind direction display
16
CLEANING AND MAINTENANCE
Before cleaning the device, disconnect it from the power supply (remove
batteries)!
Only use a dry cloth to clean the exterior of the device. To avoid damaging
the electronics, do not use any cleaning fluid.
Cleaning the rain collector (sinkhole)
Fig. 33
N
N
‚Lock‘ position ‚Unlock‘ position
1. Rotate the rain collector by 30° anticlockwise.
2. Gently remove the rain collector.
3. Clean and remove any debris or insects.
4. Install all the parts when they are fully clean and dried.
Cleaning the thermo/hygro sensor
Fig. 34
1. Unscrew the 2 screws at the bottom of the radiation shield.
2. Gently pull out the shield.
3. Remove carefully any dirt or insects inside the sensor casing
NOTE!
The radiation shield comprises different parts inserted one inside anoth-
er. Two bottom parts are closed. Do not change their order!
Do not let the sensors inside get wet!
4. Clean the shield with water and remove any dirt or insects.
5. Install all the parts back when they are fully clean and dried.
DISPOSAL
Dispose of the packaging materials properly, according to their type,
such as paper or cardboard. Contact your local waste-disposal service or
environmental authority for information on the proper disposal.
Do not dispose of electronic devices in the household garbage!
As per Directive 2012/19/EC of the European Parliament on waste
electrical and electronic equipment and its adaptation into German law,
used electronic devices must be collected separately and recycled in an
environmentally friendly manner.
In accordance with the regulations concerning batteries and re-
chargeable batteries, disposing of them in the normal household
waste is explicitly forbidden. Please make sure to dispose of your used
batteries as required by law — at a local collection point or in the retail
market. Disposal in domestic waste violates the Battery Directive.
Batteries that contain toxins are marked with a sign and a chemical sym-
bol. "Cd" = cadmium, "Hg" = mercury, "Pb" = lead.
EC DECLARATION OF CONFORMITY
Hereby, Bresser GmbH declares that the equipment type with part num-
ber: 7002510 / 7002511 / 7002512 / 7002513 / 9602510 is in compli-
ance with Directive: 2014/53/EU. The full text of the EU declaration of
conformity is available at the following internet address:
www.bresser.de/download/7002510/CE/7002510_CE.pdf
www.bresser.de/download/7002511/CE/7002511_CE.pdf
www.bresser.de/download/7002512/CE/7002512_CE.pdf
www.bresser.de/download/7002513/CE/7002513_CE.pdf
www.bresser.de/download/9602510/CE/9602510_CE.pdf
UKCA DECLARATION OF CONFORMITY
Bresser GmbH has issued a „Declaration of Conformity“ in accord-
ance with applicable guidelines and corresponding standards. The
full text of the UKCA declaration of conformity is available at the
following internet address:
http://www.bresser.de/download/7002510/UKCA/700251X_UKCA.pdf
WARRANTY
The regular warranty period is 2 years and begins on the day of purchase.
To benefit from an extended voluntary warranty period as stated on the
gift box, registration on our website is required.
You can consult the full warranty terms as well as information on extend-
ing the warranty period and details of our services at www.bresser.de/