9 Assembling the microscope

This microscope is designed for operation with a Windows PC.

For the assembly proceed as follows:

1. Screw the running rail with the preassembled microscope holder into the holding thread. Make

sure that the holder is facing forward as shown.

2.

NOTICE! For higher observation objects, the supplied extension piece can first be screwed
into the mounting thread. The rail is then screwed into the extension piece. This will increase
the working height significantly.

3. Loosen the fixing screw on the holder and unscrew it slightly so that it does not block the retaining

ring.

4. Insert the microscope head into the holder and hand-tighten the fixing screw.

10 Power supply

Plug the USB-A connector of the USB cable into a free USB port of the PC. The power is supplied
through the computer after it has been switched on. The LED ring lighting will light up.

11 Connecting to a PC

Use of this digital microscope requires a connection via USB to a PC running the Windows 10 operat-
ing system. Follow the steps below for proper connection:

1. Download and install the CamLabLite* software on the PC.

2. Mount the digital camera as described.

3. Insert the USB-A plug of the USB connection cable into a free USB port of the PC. If the connec-

tion is successful, the LED lights up. The digital microscope is ready for use.

4. The CamLabLite* software can be used to view and save images from the digital microscope. Fur-

thermore, various image optimizations can also be made. Please also read the separate software
instructions.

*Information about downloading the software and the software instructions can be found on page 2 of
this manual.

12 Adjusting the lighting

The digital microscope is equipped with a LED ring lighting for optimal object illumination and can be
dimmed continuously.

1. Connect the digital microscope to the PC.

2. Once the LED lighting is on, the brightness can be adjusted continuously by turning the dimmer

with on the USB cable.

13 Adjusting the height of the head

Depending on the size of the observation object or when changing the magnification setting, the posi-
tion of the microscope head must be adjusted in height. To do this, proceed as follows.

1. Hold the microscope head and loosen the locking screw for the holder.

2. Turn the height adjustment wheel to move the microscope head up or down in the holder.

3. Hand-tighten the locking screw when the desired height position is reached.

NOTICE! Especially when changing the zoom range, it may be necessary to additionally change
the position of the digital microscope in the holder. (see also "Focusing the object")

Summary of Contents for DST-1028

Page 1: ...Microscope Mikroskop DST 1028 EN Instruction manual DE Bedienungsanleitung ...

Page 2: ...L Bezoek onze internetpagina via de volgende QR code of weblink voor meer informatie over dit product of beschikbare vertalingen van deze gebruiksaanwijzing ES Desearía recibir unas instrucciones de uso completas sobre este producto en un idioma determinado Entonces visite nuestra página web utilizando el siguiente enlace código QR para ver las versiones disponibles IT Desidera ricevere informazio...

Page 3: ...English 4 Deutsch 10 ...

Page 4: ...r the products with the following article numbers 5808600 Manual version 1021 Manual designation Manual_5808600_DST 1028 USB Microscope_en de_BRESSER_v102021a Always provide information when requesting service 3 About this Instruction Manual NOTICE These operating instructions are to be considered a component of the device Read the safety instructions and the operating manual carefully before usin...

Page 5: ...r In case of complaints consult a doctor immediately and show the substances NOTICE Danger of material damage Improper handling may result in damage to the unit and or accessories Therefore use the device only in accordance with the following safety information Do not disassemble the device In the event of a defect please contact your dealer They will con tact the Service Center and can arrange th...

Page 6: ...er1 5 Locking screw holder 6 Wheel for height adjustment focusing 7 Fixing screw holder 8 Digital microscope holder 9 Holding thread 10 Extension piece 11 Microscope base 12 Objective 13 LED ring lighting 14 USB A connector 15 Dimmer wheel 16 Zoom ring with scale 10x to 280x 1 Function not available for this model Scope of delivery Digital microscope A with USB cable microscope stand with running ...

Page 7: ...nnection cable into a free USB port of the PC If the connec tion is successful the LED lights up The digital microscope is ready for use 4 The CamLabLite software can be used to view and save images from the digital microscope Fur thermore various image optimizations can also be made Please also read the separate software instructions Information about downloading the software and the software ins...

Page 8: ... Always hold the digital microscope firmly when loosening the locking screw or the fixing screw on the holder to prevent the digital microscope from sliding down The di gital microscope could hit the microscope base and be irreparably damaged 16 Technical data Zoom range 10x to 280x Image field 27 x 48mm 10x or 0 9 x 1 7mm 280x Working distance 10mm to 110mm Max object height approx 97mm 10x to 16...

Page 9: ...aterials properly according to their type such as paper or card board Contact your local waste disposal service or environmental authority for information on the proper disposal Do not dispose of electronic devices in the household garbage According to the European Directive 2012 19 EU on Waste Electrical and Electronic Equip ment and its transposition into national law used electrical equipment m...

Page 10: ...rodukte mit den nachfolgend aufgeführten Artikelnummern 5808600 Anleitungsversion 1021 Bezeichnung dieser Anleitung Manual_5808600_DST 1028 USB Microscope_en de_BRESSER_v102021a Informationen bei Serviceanfragen stets angeben 3 Zu dieser Anleitung HINWEIS Diese Bedienungsanleitung ist als Teil des Gerätes zu betrachten Lesen Sie vor der Benutzung des Geräts aufmerksam die Sicherheitshinweise und d...

Page 11: ...behörteile und Hilfsmittel an einem für Kinder unzu gänglichen Ort auf Es besteht Verletzungsgefahr Chemikalien und Flüssigkeiten gehören nicht in Kinderhände Nicht trinken Hände nach Gebrauch unter fließendem Wasser gründlich säubern Bei versehentlichem Kontakt mit Augen oder Mund mit Wasser spülen Bei Beschwerden unverzüglich einen Arzt aufsuchen und die Substanzen vor zeigen HINWEIS Gefahr von ...

Page 12: ...ließend gespeichert wer den Windows Version als Download verfügbar siehe Download Info auf S 2 7 Standortwahl Vor dem Aufbau und der Inbetriebnahme einen geeigneten Standort wählen Gerät auf einem stabilen ebenen und erschütterungsfreien Untergrund platzieren 8 Teileübersicht und Lieferumfang 16 14 3 7 6 8 1 4 11 10 12 2 15 9 A B C 13 5 Abb 1 Alle Teile des Digitalmikroskops DST 1028 1 Mikroskop K...

Page 13: ...g einsetzen und die Fixierschraube handfest anziehen 10 Stromversorgung herstellen Den USB A Stecker des USB Kabels in einen freien USB Port des PC stecken Die Stromversorgung erfolgt über den Computer nachdem dieser eingeschaltet wurde Die LED Ringbeleuchtung leuchtet 11 Verbindung zu einem PC herstellen Für die Verwendung dieses Digitalmikroskops ist eine Verbindung per USB zu einem PC mit dem B...

Page 14: ...Markierungspfeil zu sehen sein HINWEIS Bei einer Änderung des Zoom Bereichs muss ggf auch die Fokussierung angepasst werden siehe auch Objekt fokussieren 15 Objekt fokussieren Für eine optimale Bildschärfe muss das Beobachtungsobjekt in den Fokusbereich der Digitalkamera gebracht werden Hierzu folgendermaßen vorgehen 1 Abhängig von der Objekthöhe ggf das Verlängerungsstück montieren 2 Die erforder...

Page 15: ...808600_CE pdf 18 Entsorgung Entsorgen Sie die Verpackungsmaterialien sortenrein Informationen zur ordnungsgemäßen Entsorgung erhalten Sie beim kommunalen Entsorgungsdienstleister oder Umweltamt Werfen Sie Elektrogeräte nicht in den Hausmüll Gemäß der Europäischen Richtlinie 2012 19 EG über Elektro und Elektronik Altgeräte und deren Umsetzung in nationales Recht müssen verbrauchte Elektrogeräte get...

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ...éphone 00 800 6343 7000 BRESSER France SARL Service après vente Pôle d Activités de Nicopolis 314 Avenue des Chênes Verts 83170 Brignoles France Prix d un appel local depuis la France ou Belgique Service NL BE Als u met betrekking tot het product vragen of eventuele klachten heeft kunt u contact opnemen met het service centrum bij voorkeur per e mail e mail info bresserbenelux nl Teléfono 31 528 2...

Page 20: ...Bresser GmbH Gutenbergstraße 2 46414 Rhede Germany www bresser de BresserEurope ...

Reviews: