background image

12

REMOTE CONTROL 

The Breville air circulator comes with a remote 

control. This remote control features the same 

buttons as the control panel (except the Wi-Fi 

function) on the air circulator and can be used 

the same way.
To avoid misplacing the remote control, 

place the remote control on the right side 

of the air circulator frame with the remote 

control symbol. 
The remote control includes 1 x CR2032 3V 

Lithium battery. This Lithium battery is 

protected by an isolating slip. Before first 

using the remote control, remove the battery 

isolating slip by pulling the slip outwards away 

from the remote control. 
To check and/or to replace the battery, open 

up the battery compartment at the back of the 

remote by forming a good grip of the remote, 

pushing the small arched groove to the right 

and simultaneously pushing out the battery 

compartment cover by pushing the rectangular 

groove outwards (Fig 1a). Insert the battery 

paying attention to the polarity (+ and -).

Fig 1a

Reinsert the battery compartment into the 

remote control ensuring that the + symbol 

is facing upwards when inserted (Fig 1b). 

Make sure the battery compartment is 

correctly secured.

Fig 1b

n

 NOTE: 

To use the remote control, it must be pointed at 

the control panel and must be used within five 

meters of the air circulator. 

w

 

 

WARNING

KEEP BATTERIES OUT OF REACH OF 
CHILDREN

Swallowing may lead to serious injury in as 

little as 2 hours or death, due to chemical burns 

and potential perforation of the oesophagus. 

If you suspect your child has swallowed or 

inserted a button battery immediately call the 

24-hour Poisons Information Centre on 13 11 

26 for fast, expert advice. Examine devices 

and make sure the battery compartment is 

correctly secured, e.g. that the screw or other 

mechanical fastener is tightened. Do not use if 

compartment is not secure.
Dispose of used button batteries immediately 

and safely. Flat batteries can still be dangerous. 

Tell others about the risk associated with 

button batteries and how to keep their 

children safe.

LFA208_ANZ_IB_A20_FA.indd   12

28/5/20   5:29 pm

Summary of Contents for AirActive 3D Connect

Page 1: ...Instruction Book Suits all LFA208 Models the AirActive 3D Connect LFA208_ANZ_IB_A20_FA indd 1 28 5 20 5 29 pm...

Page 2: ...ve cover fitted to the power plug of this air circulator When unpacking the air circulator check to see you have received all the items listed in the parts list before discarding the packaging Do not...

Page 3: ...instead grasp the plug and pull to disconnect Do not pull the cord around sharp edges or corners Allow the air circulator fan blade to stop completely always switch off at the power outlet and then un...

Page 4: ...for household use only Do not use this appliance for anything other than its intended use Do not use in moving vehicles or boats Do not use outdoors Misuse may cause injury The appliance is not intend...

Page 5: ...vice centre for examination and or repair FOR HOUSEHOLD USE ONLY SAVE THESE INSTRUCTIONS The installation of a residual current device safety switch is recommended to provide additional safety protect...

Page 6: ...e C Control panel with LED display D Rear grille E Carry handle F Circulator motor head G Base H Remote control NOT PICTURED Power cord Components FRONT VIEW REAR VIEW A C B D G H E F LFA208_ANZ_IB_A2...

Page 7: ...VERTICAL OSCILLATION B MODE C POWER ON OFF D HORIZONTAL OSCILLATION E TIMER WI FI F FAN SPEED G LED DISPLAY OSC MODE OSC SPEED TIMER Control Panel C B A E F G D LFA208_ANZ_IB_A20_FA indd 7 28 5 20 5 2...

Page 8: ...lears stuffy air and creates a safe environment for the whole family WHERE TO POSITION YOUR AIR CIRCULATOR WARMER MONTHS Cool air tends to sink to the floor During warm weather point the air circulato...

Page 9: ...ards whenever the power plug is connected in particular while the air circulator is switched on nNOTE The air circulator is fitted with a power saving feature The LED display will dim after 15 seconds...

Page 10: ...and a discomfort when exposed for too long NATURAL mode generates a gentle breeze to maintain body temperature by simulating wind blowing rhythm automatically alternating wind speeds according to pre...

Page 11: ...panel The auto off timer will start on the selected mode and the mode will stop automatically once the auto off timer has expired The LED display will display the set circulator mode setting once the...

Page 12: ...aying attention to the polarity and Fig 1a Reinsert the battery compartment into the remote control ensuring that the symbol is facing upwards when inserted Fig 1b Make sure the battery compartment is...

Page 13: ...the prompts in the app 4 If the connection is successful the air circulator will appear in the main page of the app and the symbol light on the air circulator will illuminate The Breville AirActive 3D...

Page 14: ...and fan blades To clean the outside of the air circulator wipe the exterior with a soft damp cloth Never use an abrasive cleaner To clean the fan blades and remove dust that may have accumulated use a...

Page 15: ...15 Note LFA208_ANZ_IB_A20_FA indd 15 28 5 20 5 29 pm...

Page 16: ...nect are trademarks of Breville Pty Ltd Android is a trademark of Google LLC All other brands may be trademarks of their respective owners Breville s products are distributed in New Zealand under lice...