background image

11

Care, Cleaning  
& Storage

The air purifier and filter should be cleaned at 

least once every month. Ensure the air purifier  

is switched off and disconnected from the 

power outlet and allow all parts to cool before 

cleaning or storing.

• 

Use a clean, dry cloth to clean all external 

surfaces of the air purifier.

• 

Store the air purifier in an upright position.  

Do not store anything on top of the air 

purifier.

NOTE

More frequent cleaning may be required 

depending on environmental conditions.

BREVILLE RECOMMENDS

• 

Always ensure the air purifier is turned 

off, switched off at the power outlet and 

unplugged and allow the unit to cool 

before performing any cleaning or filter 

replacement.

8

8

DO NOT

 stick any foreign objects or your 

fingers inside the air inlet/outlet of this unit.

8

8

DO NOT

 use gasoline, benzine, thinner, 

harsh cleaners, etc. on and/or in the unit 

while cleaning as they will damage the unit.

8

8

NEVER

 use alcohol or other solvents  

on this unit.

CLEANING THE SENSOR 

• 

It is important to keep the air quality sensor 

clean for best performance.  

• 

The air quality sensor is situated behind a grill 

at the rear of the unit.

• 

Gently vacuum the air quality sensor grill 

using a small hand brush tool.  Cleaning 

should occur regularly, at least once a month. 

• 

If more dust can be seen on the sensor behind 

the grill then remove the cover by using the 

raised tab on the edge of the cover.  Push 

inwards and outwards simultaneously to open 

the cover, noting that it will be tight.

• 

Gently vacuum the metal shield of the air 

quality sensor using the hand brush tool.

• 

Replace the cover when clean, ensuring it 

clicks into place.

WARNING

The air quality sensor is fragile and can be 

damaged if excessive force is used during 

cleaning.  Please use extra care when cleaning.

FILTER CLEANING AND REPLACING

WARNING

The filter is not washable. Do not immerse any 

part of the air purifier in water as it will cause 

damage.

• 

The Pre-filter should be cleaned at least once 

every month using a vacuum cleaner. Gently 

vacuum using a hand-tool attachment such as 

a brush or upholstery tool. Clean more often if 

required.

• 

Do not attempt to clean the carbon filter with a 

vacuum as this can cause damage.

• 

Do not use any solutions, hard bristle  

brushes or sharp objects to clean as this  

can cause damage.

• 

Replace the filter as indicated using the 

instructions following.

LAP300_ANZ_IB_C19.indd   11

19/3/19   4:07 pm

Summary of Contents for LAP300

Page 1: ...the Smart AirTM Purifier Instruction Book LAP300 LAP300_ANZ_IB_C19 indd 1 19 3 19 4 07 pm ...

Page 2: ...and filter for the first time To eliminate a choking hazard for young children remove and safely discard the protective cover fitted to the power plug of this air purifier When unpacking the air purifier check to see you have received all the items listed in the parts list before discarding the packaging This air purifier is intended for household use only and not for commercial or industrial use ...

Page 3: ... run the power cord under carpeting or cover the power cord with rugs runners or the like Arrange the power cord away from traffic areas and where it will not be tripped over Do not route power cord under furniture or appliances Do not operate the air purifier with a damaged power cord or plug or if the air purifier has been dropped or damaged in any manner Take the air purifier to your nearest Br...

Page 4: ...ver the edge of a bench or table touch hot surfaces or become knotted To protect against electric shock do not immerse the power cord power plug or appliance in water or any other liquid or allow moisture to come in contact with the part unless it is recommended in the cleaning instructions The appliance is not intended for use by persons including children with reduced physical sensory or mental ...

Page 5: ...om the power source at the wall socket to prevent any electrical surges that may arise during the storm and which may inadvertently cause damage to the appliance and its electronic componentry Always turn the appliance to the off position switch off at the power outlet and unplug at the power outlet when the appliance is not in use Before cleaning always turn the appliance to the off position swit...

Page 6: ...trol Panel C Main Housing Body D Air Quality Sensor E Air Inlet F Microbe ShieldTM Light and Light Guard G 3 Layer Filter H Base Plate I Locking Knob NOT PICTURED Power Cord A B C D E G F H I LAP300_ANZ_IB_C19 indd 6 19 3 19 4 07 pm ...

Page 7: ...des 4 speed modes Low Medium High and Turbo E Air Quality Sensor Light The Breville Smart AirTM Purifier has a visible air quality sensor light around the control panel The light illuminates to indicate the quality of the surrounding air according to the table following E D B A C Grade Air Quality Colourof Light 1 Very Good Blue 2 Good Yellow 3 Fair Orange 4 Poor Red LAP300_ANZ_IB_C19 indd 7 19 3 ...

Page 8: ...wave UV C light specially designed to target germs and bacteria from the incoming air as it passes through the air purifier before releasing the air back into the surrounding area The Microbe ShieldTM function can be turned on and off according to preference Assembly Features BEFORE FIRST USE Remove and safely discard any packaging material or promotional labels attached to your air purifier and f...

Page 9: ... the light extinguishes to turn off this function Night Mode To turn on Night Mode press the Microbe ShieldTM NIGHT button until the night indicator light starts to blink After 10 blinks all indicator lights on the control panel will turn off as the unit enters night mode and the fan speed will automatically change to Low Press any button on the control panel to re engage the control panel and tur...

Page 10: ...rn Auto off and beneath Auto indicator light will extinguish IMPORTANT Turning the unit On and Off will require cycling through the Auto mode FILTER RESET The On Filter reset light will blink continuously indicating that the filter needs to be replaced Replace the filter according to the directions found under Replacing the Filter in this book Once the filter is replaced press and hold the POWER b...

Page 11: ...ind a grill at the rear of the unit Gently vacuum the air quality sensor grill using a small hand brush tool Cleaning should occur regularly at least once a month If more dust can be seen on the sensor behind the grill then remove the cover by using the raised tab on the edge of the cover Push inwards and outwards simultaneously to open the cover noting that it will be tight Gently vacuum the meta...

Page 12: ... filter The filter can be placed into the unit either way NOTE If the filter is not in place or not fitted correctly the air purifier will not operate WARNING Unintended use of the air purifier or damage to the housing may result in the escape of dangerous Microbe ShieldTM UV C radiation which is dangerous to the eyes and skin Never operate the UV C light outside of the air purifier UV C LIGHT CAR...

Page 13: ...correctly in place Insufficient air flow Check that the filters are clean Check for any obstructions in the air inlet and or outlet Excessive noise Check for any foreign objects that may be in contact with the fan Check if the filter is clogged and ready for replacement Check that the air purifier has been assembled correctly and the locking knob has been tightened Check that the unit is on a leve...

Page 14: ...14 NOTES LAP300_ANZ_IB_C19 indd 14 19 3 19 4 07 pm ...

Page 15: ...15 NOTES LAP300_ANZ_IB_C19 indd 15 19 3 19 4 07 pm ...

Page 16: ...le the Breville logo Master Every Moment Smart Air SensAir and the Microbe Shield logo are trademarks of Breville Pty Ltd A B N 98 000 092 928 Copyright Breville Pty Ltd 2019 Due to continued product improvement the products illustrated photographed in this booklet may vary slightly from the actual product LAP300 ANZ C19 LAP300_ANZ_IB_C19 indd 16 19 3 19 4 07 pm ...

Reviews: