background image

6

Components

A.  Air Outlet
B.  Control Panel
C.  Main Housing Body
D.  Air Quality Sensor
E.  Air Inlet
F.  Microbe Shield

TM

 Light and Light Guard

G. 3-Layer Filter
H. Base Plate
I.  Locking Knob

NOT PICTURED

Power Cord

A

B

C

D

E

G

F

H

I

LAP300_ANZ_IB_C19.indd   6

19/3/19   4:07 pm

Summary of Contents for LAP300

Page 1: ...the Smart AirTM Purifier Instruction Book LAP300 LAP300_ANZ_IB_C19 indd 1 19 3 19 4 07 pm ...

Page 2: ...and filter for the first time To eliminate a choking hazard for young children remove and safely discard the protective cover fitted to the power plug of this air purifier When unpacking the air purifier check to see you have received all the items listed in the parts list before discarding the packaging This air purifier is intended for household use only and not for commercial or industrial use ...

Page 3: ... run the power cord under carpeting or cover the power cord with rugs runners or the like Arrange the power cord away from traffic areas and where it will not be tripped over Do not route power cord under furniture or appliances Do not operate the air purifier with a damaged power cord or plug or if the air purifier has been dropped or damaged in any manner Take the air purifier to your nearest Br...

Page 4: ...ver the edge of a bench or table touch hot surfaces or become knotted To protect against electric shock do not immerse the power cord power plug or appliance in water or any other liquid or allow moisture to come in contact with the part unless it is recommended in the cleaning instructions The appliance is not intended for use by persons including children with reduced physical sensory or mental ...

Page 5: ...om the power source at the wall socket to prevent any electrical surges that may arise during the storm and which may inadvertently cause damage to the appliance and its electronic componentry Always turn the appliance to the off position switch off at the power outlet and unplug at the power outlet when the appliance is not in use Before cleaning always turn the appliance to the off position swit...

Page 6: ...trol Panel C Main Housing Body D Air Quality Sensor E Air Inlet F Microbe ShieldTM Light and Light Guard G 3 Layer Filter H Base Plate I Locking Knob NOT PICTURED Power Cord A B C D E G F H I LAP300_ANZ_IB_C19 indd 6 19 3 19 4 07 pm ...

Page 7: ...des 4 speed modes Low Medium High and Turbo E Air Quality Sensor Light The Breville Smart AirTM Purifier has a visible air quality sensor light around the control panel The light illuminates to indicate the quality of the surrounding air according to the table following E D B A C Grade Air Quality Colourof Light 1 Very Good Blue 2 Good Yellow 3 Fair Orange 4 Poor Red LAP300_ANZ_IB_C19 indd 7 19 3 ...

Page 8: ...wave UV C light specially designed to target germs and bacteria from the incoming air as it passes through the air purifier before releasing the air back into the surrounding area The Microbe ShieldTM function can be turned on and off according to preference Assembly Features BEFORE FIRST USE Remove and safely discard any packaging material or promotional labels attached to your air purifier and f...

Page 9: ... the light extinguishes to turn off this function Night Mode To turn on Night Mode press the Microbe ShieldTM NIGHT button until the night indicator light starts to blink After 10 blinks all indicator lights on the control panel will turn off as the unit enters night mode and the fan speed will automatically change to Low Press any button on the control panel to re engage the control panel and tur...

Page 10: ...rn Auto off and beneath Auto indicator light will extinguish IMPORTANT Turning the unit On and Off will require cycling through the Auto mode FILTER RESET The On Filter reset light will blink continuously indicating that the filter needs to be replaced Replace the filter according to the directions found under Replacing the Filter in this book Once the filter is replaced press and hold the POWER b...

Page 11: ...ind a grill at the rear of the unit Gently vacuum the air quality sensor grill using a small hand brush tool Cleaning should occur regularly at least once a month If more dust can be seen on the sensor behind the grill then remove the cover by using the raised tab on the edge of the cover Push inwards and outwards simultaneously to open the cover noting that it will be tight Gently vacuum the meta...

Page 12: ... filter The filter can be placed into the unit either way NOTE If the filter is not in place or not fitted correctly the air purifier will not operate WARNING Unintended use of the air purifier or damage to the housing may result in the escape of dangerous Microbe ShieldTM UV C radiation which is dangerous to the eyes and skin Never operate the UV C light outside of the air purifier UV C LIGHT CAR...

Page 13: ...correctly in place Insufficient air flow Check that the filters are clean Check for any obstructions in the air inlet and or outlet Excessive noise Check for any foreign objects that may be in contact with the fan Check if the filter is clogged and ready for replacement Check that the air purifier has been assembled correctly and the locking knob has been tightened Check that the unit is on a leve...

Page 14: ...14 NOTES LAP300_ANZ_IB_C19 indd 14 19 3 19 4 07 pm ...

Page 15: ...15 NOTES LAP300_ANZ_IB_C19 indd 15 19 3 19 4 07 pm ...

Page 16: ...le the Breville logo Master Every Moment Smart Air SensAir and the Microbe Shield logo are trademarks of Breville Pty Ltd A B N 98 000 092 928 Copyright Breville Pty Ltd 2019 Due to continued product improvement the products illustrated photographed in this booklet may vary slightly from the actual product LAP300 ANZ C19 LAP300_ANZ_IB_C19 indd 16 19 3 19 4 07 pm ...