Adjustments
Fig. 26.
Covers and access.
Warning:
Make sure installation instructions have been
followed before attempting to adjust this equipment.
Warning:
Turn off the "Power" switch, unplug the power
supply cord and allow the coffee brewer to cool before
servicing unless electrical testing is required.
Note:
Allow the coffee brewer to heat up to brewing
temperature
before
testing this equipment.
Adjusting the Faucet:
(See fig. 27)
1.
Remove the front access panel.
(Fig. 26, item 2)
.
Fig. 28.
Hi-limit location.
Fig. 27.
Faucet adjustment.
2.
Turn the faucet adjustment needle valve counterclockwise
to increase the water flow and clockwise to decrease the
water flow.
3.
Replace the front access panel, connect the power supply
cord and turn on the "Power" switch.
4. Test
thoroughly.
Note:
If the water is still not to the desired flow, repeat
the adjustment until the desired flow has been reached.
Resetting The Hi-Limit Thermostat:
(See fig. 28)
1.
Remove the top cover
(Fig. 26, item 1)
, locate the hi-limit
on the top of the tank
(Fig. 28)
.and push the red reset
button.
Caution:
Refer to the installation instructions step #12
before resetting the hi-limit thermostat. The tank must be
filled with water for the hi-limit thermostat to function
properly.
2.
Replace the top cover, connect the power supply cord and
turn on the "Power" switch. Allow the coffee brewer to
reach brewing temperature.
3. Test
thoroughly.
CAUTION:
Brewing temperatures above the maximum
recommended range may cause the hi-limit to set. Adjust
the thermostat if necessary.
WARNING:
Under no circumstance should the hi-limit thermostat be by-passed. In the event
of failure the hi-limit thermostat should be replaced. Use only original, or authorized,
replacement parts.
Page 13