Installation Instructions
Warning:
Read these installation instructions completely before connecting this coffee brewer
to a power supply or water supply. The water tank must be filled with water for this coffee
brewer to function properly.
Warning:
Incorrect installation or operating procedures will void the warranty and may
damage this coffee brewer.
Note:
Any changes to the internal plumbing or wiring of the building should be performed by a
licensed plumber or a licensed electrician. Check applicable building codes and requirements for
procedures and restrictions that may apply during this installation.
Set Up:
1.
Check the contents of the package carefully. In addition to the coffee brewer and these
instructions, the following items should be present. If any item is missing, contact Brewmatic
to arrange for a replacement.
Brew cone. (Installed on Coffee Brewer.) Clean
out
spring. (Packed inside brew cone.)
Flared nut. (Installed on water inlet fitting.)
Important Safeguard Sheet.
2.
Place the coffee brewer on a sturdy, level surface. The surface should be water and heat
resistant, non-flammable, and located near water and power supplies.
Do not connect the
power cord at this time.
Fig. 2.
Power switch.
3.
Make sure the "Power" switch
(Fig. 2)
is in the off
(down)
position.
Plumbing Connection:
(See fig. 3 on the next page for a
typical water line connection.)
Note:
This coffee brewer is designed to operate on water pressure of 30 to 80 psi. If the
water pressure exceeds 80 psi, it is recommended that a water pressure regulator
(not
included)
be installed to reduce the water pressure to 50 psi.
For an installation of less than 25 feet, use 1/4" OD copper tubing. For an installation of more
than 25 feet, use 3/8" OD copper tubing and use an adapter fitting
(not included)
for the
connection.
Depending on water conditions in your area, it is recommended that an in-line water filter or
other water filtering system
(not included)
be installed to improve the quality of the water.
It is recommended that a shut off valve
(not included)
be installed on the incoming water line
to allow the water supply to be turned off for cleaning and servicing. The shut off valve
should be installed before any water filtering system that may be installed.
Page 5
COMK211