7
Maintenance
⚫
It is very important to clean the machine after use. The dry ingredients may stick on the metal and stick inside
the pump.
⚫
Rise the machine with 5L-10L, 70-80
℃
water for 15mins or more until you make sure it is clean. Turn on the
pump during cleaning.
⚫
Do not use any sharp metal implement to remove any residue. Use a soft cloth or soft scouring pad to clean the
inside of the boiler. (vinegar can be good for this)
⚫
Any wort residue marks on the boiler base should be cleaned off before next use.
⚫
Reverse flush the pump by connecting a hose to the curved pipe.
⚫
Suitable cleaning products can be used. (please check suitability)
⚫
Do not splash any electronic parts of the machine.
⚫
Do not immerse the machine in water.
⚫
Store the machine in a dry place, do not plug in when not in use.
Troubleshooting Tips
Technical Data
Model No.:
BB-A400M-1
Volume:
40L up to top, 35L to full line
Voltage:
220V-240V
Power:
2500W
Frequency:
50Hz/60Hz
1
Ingredients stuck in the
pump
A: Flush the pump by connecting a hose to the curved pipe
B: Dismantle the pump to remove the ingredients.
2
Failing to reach 100
℃
A: Put the lid on for 1 to 2 mins
B: Make a temperature correction.
3
C1--degree centigrade
temperature correction
A: Press "-" and "+" at the same time to enter C1 temperature correction
setting. Setting range is from -10
℃
to +10
℃
, press TEMP button to
confirm.
4
F1--Fahrenheit
temperature correction
A: Press "-" and "+" at the same time to enter C1 temperature correction
setting. Setting range is from -50
℉
to +50
℉
,
press TEMP button to
confirm
5
ERR-1 shown on display
A: Temperature is lower than -20
℃
, it is low temperature warning.
B: Senor connector is loose.
C: Open the underneath and check the sensor. Re-connect it if loose.
6
ERR-2 shown on display
A: Temperature is higher than 120
℃
, it is overheat/boil-dry warning.
B: Sensor is out of order, please contact dealer for replacement.
7
Suddenly shut off during
heating
A: Lower the heat up power
B: Replace overheat protection fuse