background image

EN-2020-03 

 

 

 

 

5 | 7 

 

Tip: It is important that the electrical cords are put back at the same place as they were 
before the work started. As a help, the electrical cords can be marked with a unique 
number (1-4). Similarly, the same unique number can be written on the steel bottom. 
This way you’ll be able to fit the electrical cords back where they were before the work 
began. 

 

4.

 

When the electrical cord has been removed from the brass connector, loosen the 

heating element using a wrench or spanner on the main nut.  Remember that when 

both nuts have been removed, the heating element can drop down. It is therefore 

recommended to hold the heating element while unscrewing the last nut. 

 

5.

 

When the heating element has been removed, it is possible to either replace the 

silicone gasket or replace the heating element with a new one. If replacing the 

silicone gaskets, it is possible to take the opportunity to give the heating element a 

solid scrub or do some mechanical adjustments. The bending radius of the heating 

elements might increase slightly over time, - especially if they are run without being 

submerged in liquid.  Carefully use a suitable tool to decompress the turns to 

decrease the overall bending radius of the heating element. Be careful not to overdo 

it. Be careful not to scratch the surface of the heating elements. 

 

Summary of Contents for Pro Series

Page 1: ...EN 2020 03 1 7 Service Manual Disassemble and assemble heating elements ENGLISH ...

Page 2: ...EN 2020 03 2 7 CONTENTS Introduction 3 7 You need 3 7 Disassembly 4 7 Assembly 6 7 ...

Page 3: ...ety of the work done This is due to the potential risk of electric shock or overheating in connections that might cause a fire Performing this type of work will require the heat shrink tube to be replaced Ensure that you have heat shrink tube at hand before starting this type of work Recommended size of heat shrink tube is 10mm 3 8 with a 3x shrink factor You need Sharp knife Wrench or spanner Hea...

Page 4: ...ts the control box can be detached and temporarily removed To do this you ll need a 3mm Allen key 3 Use the sharp knife to slice the heat shrink tube from bottom to top Be careful not to damage the electrical cord outer stealth Remove the heat shrink tube to gain access to the brass connector Use the provided 1 5mm Allan key to loosen the two set screws The electrical cord will then come loose ...

Page 5: ... heating element can drop down It is therefore recommended to hold the heating element while unscrewing the last nut 5 When the heating element has been removed it is possible to either replace the silicone gasket or replace the heating element with a new one If replacing the silicone gaskets it is possible to take the opportunity to give the heating element a solid scrub or do some mechanical adj...

Page 6: ... connector and the small nut together to lock it properly It is important that the brass set screws point towards the center of the machine to enable easy access to the set screws later The brass connector and the small nut should not touch the ceramic ring 3 Put a piece of heat shrink tube on the electrical cord and put it into the brass connector Ensure that the whole tip of the electrical cord ...

Page 7: ... temperature sensor accessory plugs into Sensor 3 socket 5 If desired a cable tie can be used to organize the electrical cords 6 Turn the machine right side up Fill it with water so that the heating elements are fully covered Check that there is no leakage Tighten main heating element nuts if necessaray 7 Connect the power cables and put the machine in manual mode Turn on the heat and visually ver...