background image

EN-2020-03 

 

 

 

 

6 | 7 

 

Assembly 

 

1.

 

Put the heating element back in place and use a wrench or spanner to fasten the nut. 

Remember to refit the earthing ring lug. While fastening the nut, visually inspect the 

deforming of the silicone gasket on the inside of the vessel to ensure a good fit and a 

leak free connection. 

 

2.

 

Ensure that the brass connectors are 

fitted tightly to the heating element. It 

should not be possible to turn them by 

hand. Use two wrenches or spanners to 

tighten the brass connector and the 

small nut together to lock it properly. It 

is important that the brass set screws 

point towards the center of the 

machine to enable easy access to the 

set screws later. The brass connector 

and the small nut should not touch the 

ceramic ring.  

 

3.

 

Put a piece of heat shrink tube on the electrical cord and put it into the brass 

connector. Ensure that the whole tip of the electrical cord fits into the brass 

connector. Use the 1.5mm Allen key and tighten the brass set screws. Pull the heat 

shrink tube over the brass connector and all the way down. Use a heat shrink gun to 

shrink the heat shrink tube so that it electrically isolates and seal the whole 

connection area. 

 

    

 

Summary of Contents for Pro Series

Page 1: ...EN 2020 03 1 7 Service Manual Disassemble and assemble heating elements ENGLISH ...

Page 2: ...EN 2020 03 2 7 CONTENTS Introduction 3 7 You need 3 7 Disassembly 4 7 Assembly 6 7 ...

Page 3: ...ety of the work done This is due to the potential risk of electric shock or overheating in connections that might cause a fire Performing this type of work will require the heat shrink tube to be replaced Ensure that you have heat shrink tube at hand before starting this type of work Recommended size of heat shrink tube is 10mm 3 8 with a 3x shrink factor You need Sharp knife Wrench or spanner Hea...

Page 4: ...ts the control box can be detached and temporarily removed To do this you ll need a 3mm Allen key 3 Use the sharp knife to slice the heat shrink tube from bottom to top Be careful not to damage the electrical cord outer stealth Remove the heat shrink tube to gain access to the brass connector Use the provided 1 5mm Allan key to loosen the two set screws The electrical cord will then come loose ...

Page 5: ... heating element can drop down It is therefore recommended to hold the heating element while unscrewing the last nut 5 When the heating element has been removed it is possible to either replace the silicone gasket or replace the heating element with a new one If replacing the silicone gaskets it is possible to take the opportunity to give the heating element a solid scrub or do some mechanical adj...

Page 6: ... connector and the small nut together to lock it properly It is important that the brass set screws point towards the center of the machine to enable easy access to the set screws later The brass connector and the small nut should not touch the ceramic ring 3 Put a piece of heat shrink tube on the electrical cord and put it into the brass connector Ensure that the whole tip of the electrical cord ...

Page 7: ... temperature sensor accessory plugs into Sensor 3 socket 5 If desired a cable tie can be used to organize the electrical cords 6 Turn the machine right side up Fill it with water so that the heating elements are fully covered Check that there is no leakage Tighten main heating element nuts if necessaray 7 Connect the power cables and put the machine in manual mode Turn on the heat and visually ver...

Reviews: